Effect of vacuum drying the insulation pressboard on partial discharge characteristics under ripple voltage conditions
Yevgeniy Trotsenko,
Julia Peretyatko,
Olexandr Protsenko and
Mandar Madhukar Dixit
Additional contact information
Yevgeniy Trotsenko: National Technical University of Ukraine «Igor Sikorsky Kyiv Polytechnic Institute»
Julia Peretyatko: National Technical University of Ukraine «Igor Sikorsky Kyiv Polytechnic Institute»
Olexandr Protsenko: National Technical University of Ukraine «Igor Sikorsky Kyiv Polytechnic Institute»
Mandar Madhukar Dixit: Vishwaniketan Institute of Management Entrepreneurship and Engineering Technology
Technology audit and production reserves, 2022, vol. 2, issue 1(64), 28-33
Abstract:
The object of the research is partial discharges arising in a sample of the insulation pressboard. In most modern high-voltage direct current transmission schemes based on voltage-source converters six-pulse or twelve-pulse converters are used. The signal waveform on the direct current voltage side of a high-voltage direct current transmission is not pure direct current voltage and it has alternating current component. Since the partial discharge activity under distorted voltage is much different than that under pure direct current voltage, voltage ripples and voltage harmonics are the subject of various studies. This article examines the effect of vacuum drying the insulation pressboard on partial discharge characteristics at direct voltage ripples. The insulation pressboard was dried in a vacuum chamber with a residual pressure of 1 mm Hg. Among all the characteristics of a partial discharge, the main focus has been on the apparent charge of a partial discharge. The greater is the apparent charge value, the stronger is the destructive effect on high-voltage insulation. It was shown that drying the insulation in a vacuum chamber has the greatest effect on reducing the apparent charge of a partial discharge at direct current voltage than at alternating current voltage. After drying the insulation in a vacuum chamber, the amplitude of the partial discharge pulses was decreased by 99.3 % at direct current voltage in comparison with the moistened sample. After vacuum drying, at DC voltage, rare and very low magnitude partial discharges were recorded. The conducted research contributes to the development of methods for partial discharge detection under non-standard voltage conditions.
Keywords: partial discharge; ripple voltage; insulation pressboard; vacuum drying (search for similar items in EconPapers)
Date: 2022
References: Add references at CitEc
Citations:
Downloads: (external link)
https://journals.uran.ua/tarp/article/view/256564/254431 (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:baq:taprar:v:2:y:2022:i:1:p:28-33
DOI: 10.15587/2706-5448.2022.256564
Access Statistics for this article
More articles in Technology audit and production reserves from PC TECHNOLOGY CENTER
Bibliographic data for series maintained by Iryna Prudius ().