The Quality of Shallow Underground Well-Water in Sapele Local Government Area of Delta State, Nigeria, West Africa
Okonkwo Na,
Ikeh Oa,
Anarado Il,
Igwilo Mo,
Aduaka Cn and
A Igberease
Additional contact information
Okonkwo Na: Department of Pure and Industrial Chemistry, Nnamdi Azikiwe University, Awka, Anambra State, Nigeria
Ikeh Oa: Department of Pure and Industrial Chemistry, Nnamdi Azikiwe University, Awka, Anambra State, Nigeria
Anarado Il: Department of Pure and Industrial Chemistry, Nnamdi Azikiwe University, Awka, Anambra State, Nigeria
Igwilo Mo: Department of Pure and Industrial Chemistry, Nnamdi Azikiwe University, Awka, Anambra State, Nigeria
Aduaka Cn: Department of Pure and Industrial Chemistry, Nnamdi Azikiwe University, Awka, Anambra State, Nigeria
A Igberease: Department of Industrial Chemistry, Madonna University, Elele, Rivers State, Nigeria
International Journal of Research and Innovation in Applied Science, 2024, vol. 9, issue 12, 20-26
Abstract:
Well water samples were taken from six different locations at Sapele Local Government Area in Delta State, Nigeria. The samples were properly collected and in-situ analysis were done for some physicochemical parameters such as conductivity, turbidity, pH and temperature using a calibrated Search Tech, PHS-7010 multimeter. The Chloride, calcium, alkalinity and total hardness determinations were done titrimetrically while gravimetric method was used to analyze the total dissolved solids and total suspended solids of the water samples. The concentrations of heavy metals (zinc, lead and cadmium) were assayed using Varian AA240 atomic absorption spectrometer (AAS). Additionally, bacteriological examination of the water samples was conducted using Inoculation method to determine the level of microbial contamination such as faecal coliform and Escherichia coli (E. coli) count, to assess the water qualities potential health risks. The results obtained from physicochemical analysis gave the following range: conductivity (110.6 – 130.7µs/cm), pH (5.00 – 6.90), temperature (21.00 – 23.00 0C), chloride (0.00 – 17.70mg/L), Calcium (0.00 – 1.92mg/L), total dissolved solids (50.90 – 69.20 mg/L), turbidity (0.00 – 2.00 NTU), alkalinity (10.80 – 13.60 mg/L), total hardness (6.28- 8.65mg/L) and total suspended solids (not detected in any of the samples). Concentrations of the heavy metals determination showed that Zn ranged from 0.012 – 0.080mg/L, there was no trace of Pb and Cd. Bacteriological analysis indicated that samples did not meet the standard of world health organization (WHO) as they contained fecal coliforms (1.4×102 – 7×102 CFU/mL). Based on the results obtained from all the analysis, the physicochemical parameters and heavy metals fell under permissible limit by world health organization (WHO) but bacteriological parameters did not. Hence, the water should be treated before consumption.
Date: 2024
References: Add references at CitEc
Citations:
Downloads: (external link)
https://www.rsisinternational.org/journals/ijrias/ ... 9-issue-12/20-26.pdf (application/pdf)
https://rsisinternational.org/journals/ijrias/arti ... nigeria-west-africa/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:bjf:journl:v:9:y:2024:i:12:p:20-26
Access Statistics for this article
International Journal of Research and Innovation in Applied Science is currently edited by Dr. Renu Malsaria
More articles in International Journal of Research and Innovation in Applied Science from International Journal of Research and Innovation in Applied Science (IJRIAS)
Bibliographic data for series maintained by Dr. Renu Malsaria ().