Determination of free and bound 3-chloropropane-1,2-diol by gas chromatography with mass spectrometric detection using deuterated 3-chloropropane-1,2-diol as internal standard
V. Divinová,
B. Svejkovská,
M. Doležal and
J. Velíšek
Additional contact information
V. Divinová: Department of Food Chemistry and Analysis, Faculty of Food and Biotechnological Technology, Institute of Chemical Technology in Prague, Prague, Czech Republic
B. Svejkovská: Department of Food Chemistry and Analysis, Faculty of Food and Biotechnological Technology, Institute of Chemical Technology in Prague, Prague, Czech Republic
M. Doležal: Department of Food Chemistry and Analysis, Faculty of Food and Biotechnological Technology, Institute of Chemical Technology in Prague, Prague, Czech Republic
J. Velíšek: Department of Food Chemistry and Analysis, Faculty of Food and Biotechnological Technology, Institute of Chemical Technology in Prague, Prague, Czech Republic
Czech Journal of Food Sciences, 2004, vol. 22, issue 5, 182-189
Abstract:
An improved routine, simple and sensitive method is presented for the determination of free and bound 3-chloropropane-1,2-diol (3-MCPD) in different foods using capillary gas chromatography with mass spectrometric detection and deuterated 3-MCPD as internal standard. The optimised method was linear within the working calibration standard concentrations in the range of 0.009-1.3 mg 3-MCPD per 1 kg of sample. The LOD and LOQ were 0.003 µg/kg and 0.009 µg/kg, respectively. Validation of the method was carried out by analysing standards of 3-MCPD, acid-HVP, roasted coffee samples, and the same samples spiked with 3-MCPD. Repeatability (expressed as RSD) of the method was in the range 1.0-4.2%, the average spike recoveries were 99.1-99.5% (RSD = 0.8-1.4%), respectively. 3-MCPD bound in esters with higher fatty acids was isolated as fat, the isolated fat was subjected to methanolysis and 3-MCPD generated was quantified using the same method. The LOD and LOQ were determined to be 1.1 mg/kg of lipids and 3.3 mg/kg of lipids, respectively. Using the optimised method, 20 samples of retail food products were analysed for their free and bound 3-MCPD. All samples contained free 3-MCPD at 9.6-83 µg/kg (RSD = 0.4-7.0%). The level of the bound 3-MCPD varied between the LOD and 2.4 mg/kg with RSD = 0.3-2.4%.
Keywords: 3-chloropropane-1; 2-diol (3-MCPD); chloropropanediols; 3-MCPD esters; phenylboronic acid; food analysis (search for similar items in EconPapers)
Date: 2004
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
http://cjfs.agriculturejournals.cz/doi/10.17221/3422-CJFS.html (text/html)
http://cjfs.agriculturejournals.cz/doi/10.17221/3422-CJFS.pdf (application/pdf)
free of charge
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:caa:jnlcjf:v:22:y:2004:i:5:id:3422-cjfs
DOI: 10.17221/3422-CJFS
Access Statistics for this article
Czech Journal of Food Sciences is currently edited by Ing. Zdeňka Náglová, Ph.D.
More articles in Czech Journal of Food Sciences from Czech Academy of Agricultural Sciences
Bibliographic data for series maintained by Ivo Andrle ().