The influence of housing systems on the air quality and bacterial eggshell contamination of table eggs
M. Vučemilo,
B. Vinković,
K. Matković,
I. Štoković,
S. Jakšić,
S. Radović,
K. Granić and
Đ. Stubičan
Additional contact information
M. Vučemilo: Department of Animal Hygiene, Environment and Ethology, Faculty of Veterinary Medicine, University of Zagreb, Zagreb, Croatia
B. Vinković: Laboratory of Ecology, Croatian Veterinary Institute, Zagreb, Croatia
K. Matković: Department of Animal Hygiene, Environment and Ethology, Faculty of Veterinary Medicine, University of Zagreb, Zagreb, Croatia
I. Štoković: Department of Stockbreeding, Faculty of Veterinary Medicine, University of Zagreb, Zagreb, Croatia
S. Jakšić: ZIN-LAB Laboratory for Foodstuffs of Animal Origin, Zagreb Veterinary Clinic, Zagreb, Croatia
S. Radović: Inspection Directorate, Ministry of Environmental Protection, Physical Planning and Construction, Zagreb, Croatia
K. Granić: ZIN-LAB Laboratory for Foodstuffs of Animal Origin, Zagreb Veterinary Clinic, Zagreb, Croatia
Đ. Stubičan: Library, Faculty of Veterinary Medicine, University of Zagreb, Zagreb, Croatia
Czech Journal of Animal Science, 2010, vol. 55, issue 6, 243-249
Abstract:
This paper compares two different housing systems for laying hens producing table eggs, namely a conventional cage system and an aviary, during three summer months, starting from the 20th week of the production cycle. Research was focused on airborne bacteria, fungi and dust levels and on the bacterial eggshell contamination. Levels of airborne bacteria determined in the aviary system were many times higher and ranged from 6.2 × 104 CFU/m3 to 8.9 × 104 CFU/m3, and the levels of airborne fungi ranged from 1.6 × 104 to 1.9 × 104 CFU/m3, while the levels of airborne bacteria and fungi determined in the conventional cage system ranged from 1.6 × 104 to 2.5 × 104 CFU/m3 and from 0.8 × 104 to 1.3 × 104 CFU/m3, respectively. Microbial air contamination was associated with eggshell contamination, with the levels in the aviary ranging from 5.4 × 103 to 9.6 × 103 CFU/eggshell and those in the conventional cage system ranging from 2.3 × 103 to 3.6 × 103 CFU/eggshell. Airborne dust levels in the aviary and conventional cage system ranged from 3.2 to 4.6 mg/m3 and from 0.7 to 1.2 mg/m3, respectively. From the aspect of animal welfare and behavioural requirements, alternative systems, i.e. aviaries, appear more acceptable; however, they are not satisfactory from hygienic aspects because of a higher content of airborne pollutants which can represent a greater risk of horizontal contamination of the egg content.
Keywords: conventional cage system; aviary; air hygiene; eggshell; microorganisms (search for similar items in EconPapers)
Date: 2010
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
http://cjas.agriculturejournals.cz/doi/10.17221/64/2009-CJAS.html (text/html)
http://cjas.agriculturejournals.cz/doi/10.17221/64/2009-CJAS.pdf (application/pdf)
free of charge
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:caa:jnlcjs:v:55:y:2010:i:6:id:64-2009-cjas
DOI: 10.17221/64/2009-CJAS
Access Statistics for this article
Czech Journal of Animal Science is currently edited by Bc. Michaela Polcarová
More articles in Czech Journal of Animal Science from Czech Academy of Agricultural Sciences
Bibliographic data for series maintained by Ivo Andrle ().