The laboratory calibration of a soil moisture capacitance probe in sandy soils
Marina Campora,
Anna Palla,
Ilaria Gnecco,
Rossella Bovolenta and
Roberto Passalacqua
Additional contact information
Marina Campora: Genoa, Italy
Anna Palla: Department of Civil, Chemical and Environmental Engineering, University of Genoa, Genoa, Italy
Ilaria Gnecco: Department of Civil, Chemical and Environmental Engineering, University of Genoa, Genoa, Italy
Rossella Bovolenta: Department of Civil, Chemical and Environmental Engineering, University of Genoa, Genoa, Italy
Roberto Passalacqua: Department of Civil, Chemical and Environmental Engineering, University of Genoa, Genoa, Italy
Soil and Water Research, 2020, vol. 15, issue 2, 75-84
Abstract:
Determining and mitigating landslide risk is a technical-scientific objective, particularly for the protection and proper territorial management and planning. The slope stability depends on the pore pressure distribution, which is influenced by the saturation front propagation through the unsaturated zone, whose monitoring is useful to understand any possible instabilities. Such monitoring may be undertaken by sensors based on the measurement of the relative dielectric permittivity. Reliable relationships between the measurement and the soil moisture are necessary. The main objective of this study is to assess a laboratory calibration protocol for a specific capacitance sensor (Drill & Drop, Sentek Sensor Technologies). Two monogranular sands have been selected for the calibration purpose. The laboratory tests were performed under three relative density values (DR equal to 40%, 60% and 80%) for seven volumetric water content values (θv ranging from 0.00% to 36.26%). Based on the experimental measurements, the soil-specific calibration curves were determined at an assigned relative density value; in particular, a simple power law is adopted to describe the probe's reading as a function of the volumetric water content. The results point out that the relative density values slightly affect the tests, thus, the soil-specific calibration curves are derived based on a simple regression analysis fitting the whole set of the laboratory tests validated for each sand. The calculated coefficient of determination (R2 = 0.96/0.99) and root mean square error (RMSE = 1.4%/2.8%) values confirm the goodness of fit. In order to propose more general fitting curves, suitable for both the investigated sands, multiple linear regressions are performed by considering θv and the mean grain size, D50 as independent variables; again, the R2 and RMSE values equal to 0.97 and 2.41%, respectively, confirm the suitability of the calibration curve. Finally, the laboratory calibration curves are compared with the manufacturer-supplied curves, thus, enhancing the need for the soil-specific calibration.
Keywords: particle size distribution; regression analysis; relative density; soil water monitoring; volumetric water content (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
http://swr.agriculturejournals.cz/doi/10.17221/227/2018-SWR.html (text/html)
http://swr.agriculturejournals.cz/doi/10.17221/227/2018-SWR.pdf (application/pdf)
free of charge
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:caa:jnlswr:v:15:y:2020:i:2:id:227-2018-swr
DOI: 10.17221/227/2018-SWR
Access Statistics for this article
Soil and Water Research is currently edited by Ing. Markéta Knížková, (Executive Editor)
More articles in Soil and Water Research from Czech Academy of Agricultural Sciences
Bibliographic data for series maintained by Ivo Andrle ().