Comparison of two sensors ECH2O EC-5 and SM200 for measuring soil water content
Radka Kodešová,
Vít Kodeš and
Arnošt Mráz
Additional contact information
Radka Kodešová: Department of Soil Science and Soil Protection, Faculty of Agrobiology, Food and Natural Resources, Czech University of Life Sciences Prague, Prague, Czech Republic;
Vít Kodeš: Department of Soil Science and Soil Protection, Faculty of Agrobiology, Food and Natural Resources, Czech University of Life Sciences Prague, Prague, Czech Republic;
Arnošt Mráz: Ekotechnika, Ltd., Černošice, Czech Republic$2
Soil and Water Research, 2011, vol. 6, issue 2, 102-110
Abstract:
The goal of this study was calibration of the ECH20 soil moisture sensor EC-5 and the sensor SM200 for selected soils of the Czech Republic. Based on the soil maps of the Czech Republic and various climatic conditions, five humic horizons of different soil types were selected: Stagnic Chernozem Siltic, Haplic Chernozem, Chernozem Arenic, Haplic Luvisol, and Haplic Cambisol. Soil properties (pHKCl, pHH2O, exchangeable acidity, cation exchange capacity, hydrolytic acidity, basic cation saturation, sorption complex saturation, oxidable organic carbon content, CaCO3 content, salinity, sand, silt, and clay content, soil particle density, bulk density) were determined using the standard laboratory techniques. Six ECH20 EC-5 sensors permanently installed in six 606 cm3 repacked soil samples of each soil were calibrated. Four calibrated SM200 sensors were inserted into the same soil samples only when measuring sensor signal. Soil water contents were determined gravimetrically. Linear equation was used to find parameters of the calibration equations relating sensor signals or evaluated dielectric constants and soil water contents. The multiple linear analyses showed that the parameters of the calibration equations for the EC-5 depended on the bulk density, fraction of sand particles, and salinity. Parameters a and b of the SM200 depended on the initial soil salinity, sand fraction and CaCO3 content, and on the sand fraction, respectively. The impact of KBr solute (concentrations of 0.01, 0.05 and 0.1M Br) on calibration equations was studied as well. It was found that ECH20 EC-5 sensor measurements were more influenced by KBr solution than SM200 measurements. In the case of the ECH20 EC-5 sensor, impact of KBr was lower in soils of higher initial salinity. SM200 measurements were noticeably influenced only when 0.1M Br solution was applied.
Keywords: bulk density; CaCO3; ECH20 soil moisture sensor EC-5; fraction of sand particles; SM200 sensor; soil and soil water salinity; soils of the Czech Republic; soil water content (search for similar items in EconPapers)
Date: 2011
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
http://swr.agriculturejournals.cz/doi/10.17221/6/2011-SWR.html (text/html)
http://swr.agriculturejournals.cz/doi/10.17221/6/2011-SWR.pdf (application/pdf)
free of charge
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:caa:jnlswr:v:6:y:2011:i:2:id:6-2011-swr
DOI: 10.17221/6/2011-SWR
Access Statistics for this article
Soil and Water Research is currently edited by Ing. Markéta Knížková, (Executive Editor)
More articles in Soil and Water Research from Czech Academy of Agricultural Sciences
Bibliographic data for series maintained by Ivo Andrle ().