EconPapers    
Economics at your fingertips  
 

Evaluation of platelet function in horses undergoing colic surgery using the PFA-100 platelet function analyser

A. Iwaszko-Simonik and S. Graczyk
Additional contact information
A. Iwaszko-Simonik: Department of Immunology, Pathophysiology and Veterinary Preventive Medicine, Wroclaw University of Environmental and Life Sciences, Wroclaw, Poland
S. Graczyk: Department of Immunology, Pathophysiology and Veterinary Preventive Medicine, Wroclaw University of Environmental and Life Sciences, Wroclaw, Poland

Veterinární medicína, 2015, vol. 60, issue 9, 476-482

Abstract: Acute colic in horses, especially presentations requiring surgical correction, such as large colon volvulus, very often involves defective or excess platelet activation. The PFA-100 is a new point-of-care analyser that evaluates platelet function by measuring closure time (CT) in the whole blood of healthy horses in a standardised manner. However, there are no reports on platelet function in horses with colic measured by the PFA-100. The aim of the present study was to investigate platelet function in a group of horses suffering ascending colon displacement (ACD) and who underwent surgery compared to a group of control (C) horses. Thirty ACD cases and twenty untreated clinically healthy control horses were included. Blood samples were collected from the ACD horses prior to and 24, 48 and 72 h after laparotomy. Red blood cell count (RBC), haematocrit (HCT), haemoglobin (Hb) concentration, white blood cell count (WBC), total plasma protein (TP) concentration, platelet count (PLT), platelet volume (MPV) and ADP closure time (CT-ADP) were measured. CT was determined on a PFA-100® device using collagen/ADP cartridges. There were no significant differences in RBC, PLT and MPV between C and ACD horses pre-operatively. Reduced PLT was observed in the post-operative period. The mean CT-ADP of C horses was 96.43 ± 12.53 and 91.43 ± 2.51 seconds in the ACD group prior to surgery. CT-ADP was changed after surgery whereby CT-ADP time was more than doubled. We conclude that the PFA-100® can be used to detect platelet function defects in horses.

Keywords: colic; closure time; ascending colon displacement; PFA-100; platelets; horse (search for similar items in EconPapers)
Date: 2015
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
http://vetmed.agriculturejournals.cz/doi/10.17221/8438-VETMED.html (text/html)
http://vetmed.agriculturejournals.cz/doi/10.17221/8438-VETMED.pdf (application/pdf)
free of charge

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:caa:jnlvet:v:60:y:2015:i:9:id:8438-vetmed

DOI: 10.17221/8438-VETMED

Access Statistics for this article

Veterinární medicína is currently edited by Ing. Helena Smolová Ph.D.

More articles in Veterinární medicína from Czech Academy of Agricultural Sciences
Bibliographic data for series maintained by Ivo Andrle ().

 
Page updated 2025-03-19
Handle: RePEc:caa:jnlvet:v:60:y:2015:i:9:id:8438-vetmed