EconPapers    
Economics at your fingertips  
 

Computed tomographic features of tracheal shapes and dimensions in awake dogs

S. Lim, J. Jeong, H.G. Heng, S. Sung, Yoonseok Choi, H. Oh, K. Kim, Y. Cho, Y. Jung and K. Lee
Additional contact information
S. Lim: Chonbuk National University of Veterinary Clinical Science, Iksan-si, Republic of Korea
J. Jeong: Chonbuk National University of Veterinary Clinical Science, Iksan-si, Republic of Korea
H.G. Heng: Purdue University College of Veterinary Medicine, West Lafayette, USA
S. Sung: Chonbuk National University of Veterinary Clinical Science, Iksan-si, Republic of Korea
H. Oh: Chonbuk National University of Veterinary Clinical Science, Iksan-si, Republic of Korea
K. Kim: Chonbuk National University of Veterinary Clinical Science, Iksan-si, Republic of Korea
Y. Cho: College of Health Sciences, Cheongju University, Cheongju, Republic of Korea
Y. Jung: Research Ethics Center, Office of Research Management, Korea University, Seoul, Republic of Korea
K. Lee: Chonbuk National University of Veterinary Clinical Science, Iksan-si, Republic of Korea

Veterinární medicína, 2018, vol. 63, issue 3, 131-136

Abstract: There are several reports in the veterinary literature on tracheal assessment; however, there is a lack of studies on the trachea in voluntarily breathing dogs. The aim of this study was to describe the natural shape of the trachea in awake dogs and to assess tracheal dimensions and the width-to-height ratio. Thoracic computed tomographic images of awake small breed dogs without any signs of respiratory malfunction (n = 19) were evaluated. Each trachea was categorised into one of four different shapes: circular, horseshoe, crescent or focal dorsal invagination. The circular shape was prominent, particularly in the thoracic inlet and intrathoracic area, while the horseshoe shape was also normally present. In this group of normal dogs, there were no crescent-shaped tracheas, but focally invaginated tracheas were observed. The mean tracheal heights at five locations, namely the caudal endplate of the fourth cervical vertebra, cranial endplate of the seventh cervical vertebra, mid-body of the first thoracic vertebra, mid-body of the third thoracic vertebra, and 1 cm cranial to the carina were 9.12, 8.96, 9.34, 9.88 and 10.16 mm, respectively. The widths at these same sites were 12.26, 10.42, 10.07, 9.82 and 10.23 mm, respectively. The width-to-height ratios of each tracheal location were 1.38, 1.20, 1.10, 1.01 and 1.03, the last two of which are consistent with the circular shape of the intrathoracic trachea. Multi-detector computed tomography under non-general anaesthesia is a non-invasive and unparalleled imaging tool for describing tracheal appearance in healthy awake dogs.

Keywords: anaesthesia-free procedure; trachea; shape; diameter; computed tomography (search for similar items in EconPapers)
Date: 2018
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
http://vetmed.agriculturejournals.cz/doi/10.17221/124/2017-VETMED.html (text/html)
http://vetmed.agriculturejournals.cz/doi/10.17221/124/2017-VETMED.pdf (application/pdf)
free of charge

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:caa:jnlvet:v:63:y:2018:i:3:id:124-2017-vetmed

DOI: 10.17221/124/2017-VETMED

Access Statistics for this article

Veterinární medicína is currently edited by Ing. Helena Smolová Ph.D.

More articles in Veterinární medicína from Czech Academy of Agricultural Sciences
Bibliographic data for series maintained by Ivo Andrle ().

 
Page updated 2025-03-19
Handle: RePEc:caa:jnlvet:v:63:y:2018:i:3:id:124-2017-vetmed