Transscleral ultrasonographic measurements of the optic nerve sheath diameter and a regression analysis with morphometric measures of the globe in dogs
M Vinas,
U Zeyen,
N D'Anna and
M Vignoli
Additional contact information
M Vinas: CVRS - Policlinico Veterinario Roma Sud - Servizio di Oftalmologia, Roma, Italy
U Zeyen: Centro Veterinario Specialistico, CVS, Servizio di Ecografia, Roma, Italy
N D'Anna: CVRS - Policlinico Veterinario Roma Sud - Servizio di Oftalmologia, Roma, Italy
M Vignoli: Faculty of Veterinary Medicine, University of Teramo, Teramo, Italy
Veterinární medicína, 2019, vol. 64, issue 11, 490-496
Abstract:
To describe transscleral ultrasonography as a novel alternative approach for visualising the optic nerve sheath and measuring its diameter and to analyse the linear regressions of the optic nerve sheath diameter value with the weights and morphometric measurements of the globe in dogs. Forty healthy dogs admitted for routine sterilisation were examined. Under general anaesthesia, a B-mode ultrasonography with a linear probe (9-18 MHz) was applied transscleral in the dorso-temporal quadrant. The optic nerve sheath diameter was measured 3 mm behind the caudal aspect of the globe. The morphometric measurements, including the axial globe, lens thickness and vitreous chamber, were estimated by two observers using the direct corneal approach. Univariate and multivariate multiple linear regression analyses were performed to explore the associations of the independent predictors with dependent variables. The optic nerve sheath diameter intraclass correlation coefficient (ICC) analyses revealed interobserver 0.91 (ICC = 0.83-0.95) and intraobserver 0.93 (ICC = 0.87-0.96) reliability. The multiple regression analysis revealed that the optic nerve sheath diameter was associated with the weight (R2 = 0.60, P < 0.0001) but not with the axial globe (P = 0.48), the lens thickness (P = 0.73) or the vitreous chamber (P = 0.99). The findings of this study suggest that transscleral ultrasonography may be a valid alternative approach for the optic nerve visualisation and optic nerve sheath diameter measurements with excellent intra- and interobserver repeatability. The optic nerve sheath diameter was associated with the body weight, but not with the morphometric measurements of the globe.
Keywords: morphometry; canine; intracranial pressure; ocular ultrasound; body weight (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
http://vetmed.agriculturejournals.cz/doi/10.17221/39/2019-VETMED.html (text/html)
http://vetmed.agriculturejournals.cz/doi/10.17221/39/2019-VETMED.pdf (application/pdf)
free of charge
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:caa:jnlvet:v:64:y:2019:i:11:id:39-2019-vetmed
DOI: 10.17221/39/2019-VETMED
Access Statistics for this article
Veterinární medicína is currently edited by Ing. Helena Smolová Ph.D.
More articles in Veterinární medicína from Czech Academy of Agricultural Sciences
Bibliographic data for series maintained by Ivo Andrle ().