EconPapers    
Economics at your fingertips  
 

Evaluation of radiation exposure from fluoroscopic examination in small animal veterinary staff using thermoluminescent dosimeters

Jeongsu An, Sohee Lim, Seunghee Lee, Hyeona Kim, Kyungjun Min, Youngkwon Cho and Kichang Lee
Additional contact information
Jeongsu An: College of Veterinary Medicine, Chonbuk National University, Iksan, Republic of Korea
Sohee Lim: College of Veterinary Medicine, Chonbuk National University, Iksan, Republic of Korea
Seunghee Lee: College of Veterinary Medicine, Chonbuk National University, Iksan, Republic of Korea
Hyeona Kim: College of Veterinary Medicine, Chonbuk National University, Iksan, Republic of Korea
Kyungjun Min: College of Veterinary Medicine, Chonbuk National University, Iksan, Republic of Korea
Youngkwon Cho: College of Health Sciences, Cheongju University, Cheongju, Republic of Korea
Kichang Lee: College of Veterinary Medicine, Chonbuk National University, Iksan, Republic of Korea

Veterinární medicína, 2019, vol. 64, issue 6, 266-270

Abstract: The purpose of this study was to evaluate the occupational radiation exposure levels of veterinary staff during fluoroscopic examination using thermoluminescent dosimeters (TLDs). A prospective study was conducted to measure radiation doses in three positioned persons (two restrainers and one observer) using TLDs. The TLDs were placed on the inside and outside of the lead-equivalent protective devices of the panorama mask, thyroid shield, apron and arm shield. The TLDs were placed at five anatomic sites (eye, thyroid, breast, gonad and hand). Radiation exposure was measured in 65 fluoroscopic examinations at 80 kVp and 100 mAs. The doses (mSv) (outside/inside the shield) measured in restrainers A and B and observer C were 3.09/0.59, 3.80/0.65 and 0.63/0.44 in the eye; 2.20/0.73, 1.88/1.10 and 0.79/0.45 in the thyroid; 3.42/0.44, 3.94/2.35 and 0.61/0.34 in the breast; 1.84/0.45, 1.69/0.23 and 0.46/0.36 in the gonad; and 5.56/3.16, 8.29/2.99 and 0.79/0.34 in the hand, respectively. Out of all the lead protection devices, the radiation dose of the hand was the highest in all three participants, with the thyroid radiation dose value being the same as the hand in the observer C. Radiation doses received by the eyes of all three participants were also not negligible. Veterinary workers exposed to radiation through not only radiography but also fluoroscopy should wear protective gear, especially for the eyes.

Keywords: eye exposure; radiation exposure; thermoluminescent dosimeter; small animal; fluoroscopy (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
http://vetmed.agriculturejournals.cz/doi/10.17221/141/2018-VETMED.html (text/html)
http://vetmed.agriculturejournals.cz/doi/10.17221/141/2018-VETMED.pdf (application/pdf)
free of charge

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:caa:jnlvet:v:64:y:2019:i:6:id:141-2018-vetmed

DOI: 10.17221/141/2018-VETMED

Access Statistics for this article

Veterinární medicína is currently edited by Ing. Helena Smolová Ph.D.

More articles in Veterinární medicína from Czech Academy of Agricultural Sciences
Bibliographic data for series maintained by Ivo Andrle ().

 
Page updated 2025-03-19
Handle: RePEc:caa:jnlvet:v:64:y:2019:i:6:id:141-2018-vetmed