Comparison of three ECG machines for electrocardiography in green iguanas (Iguana iguana)
E Cermakova,
A Piskovska,
V Trhonova,
L Schilliger and
Z Knotek
Additional contact information
E Cermakova: Avian and Exotic Animal Clinic, Faculty of Veterinary Medicine, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic
A Piskovska: Private Veterinarian, Nové Veselí, Czech Republic
V Trhonova: Avian and Exotic Animal Clinic, Faculty of Veterinary Medicine, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic
L Schilliger: Clinique Vétérinaire du Village d'Auteuil, Paris, France
Z Knotek: Avian and Exotic Animal Clinic, Faculty of Veterinary Medicine, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic
Veterinární medicína, 2021, vol. 66, issue 2, 66-71
Abstract:
The aim of the study was to compare the heart rate, QRS interval, and R wave amplitude across three electrocardiogram models, and assess the ability of each of them to provide electrocardiograms (ECG) for clinical interpretation. The three electrocardiogram models included ECG Seiva Praktik Veterinary, CardioStore ECG and AliveCor Veterinary Heart Monitor. The data were collected from twelve healthy adult captive green iguanas (Iguana iguana) monitored under a manual restraint at a room temperature of 22.6-28.0 °C. The ECGs using the Seiva Praktik and CardioStore ECG veterinary electrocardiography were performed with standard 4 lead ECG recordings. The AliveCor Veterinary Heart Monitor was placed (with the use of gel) directly on the lateral body wall. The mean heart rate was 42 ± 8 beats/min (CardioStore), 50 ± 11 beats/min (Seiva Praktik Veterinary), and 51 ± 9 beats/min (AliveCor Veterinary Heart Monitor). No significant difference in the heart rate was observed. A significant difference (P < 0.05) in the QRS duration was observed between the CardioStore and AliveCor Veterinary Heart Monitor. Significant differences (P < 0.01) in the R wave amplitude were detected between the CardioStore and AliveCor Veterinary Heart Monitor and between the Seiva Praktik Veterinary and AliveCor Veterinary Heart Monitor. The ECGs produced by the Seiva Praktik VVeeterinary and CardioStore machines were interpretable at 100%, while those produced by the AliveCor Veterinary Heart Monitor were interpretable at 66%. Seiva Praktik Veterinary is most appropriately used as an anaesthesia monitoring tool. AliveCor Veterinary Heart Monitor could be used as an additional diagnostic tool, but the results should be ideally confirmed with a standard ECG machine. Seiva Praktik Veterinary is the most appropriate tool for monitoring the ECG within the anaesthesia, while CardioStore might be most appropriately used as an advanced diagnostic tool by virtue of its software assistance. The ECGs obtained with AliveCor Veterinary Heart Monitor should be confirmed using a standard ECG machine.
Keywords: reptile cardiology; reptile electrocardiogram; heart frequency; R wave; QRS complex (search for similar items in EconPapers)
Date: 2021
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
http://vetmed.agriculturejournals.cz/doi/10.17221/39/2020-VETMED.html (text/html)
http://vetmed.agriculturejournals.cz/doi/10.17221/39/2020-VETMED.pdf (application/pdf)
free of charge
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:caa:jnlvet:v:66:y:2021:i:2:id:39-2020-vetmed
DOI: 10.17221/39/2020-VETMED
Access Statistics for this article
Veterinární medicína is currently edited by Ing. Helena Smolová Ph.D.
More articles in Veterinární medicína from Czech Academy of Agricultural Sciences
Bibliographic data for series maintained by Ivo Andrle ().