EconPapers    
Economics at your fingertips  
 

Preparation of artificial vascularised tissue and the indirect determination of its void volume using µCT

C Seiler, M Luepke, Bach Jp and H Seifert
Additional contact information
C Seiler: Institute of General Radiology and Medical Physics, University of Veterinary Medicine Foundation, Hannover, Germany
M Luepke: Institute of General Radiology and Medical Physics, University of Veterinary Medicine Foundation, Hannover, Germany
Bach Jp: Small Animal Clinic, University of Veterinary Medicine Foundation, Hannover, Germany
H Seifert: Institute of General Radiology and Medical Physics, University of Veterinary Medicine Foundation, Hannover, Germany

Veterinární medicína, 2022, vol. 67, issue 7, 387-394

Abstract: The non-invasive determination of the vasculature volume would be very useful in many fields of medicine such as oncology and implantation. The purpose of this research was, therefore, to develop a methodology to investigate vascularisation in phantoms using microcomputed tomography (μCT) without having to visualise the single vessels. Epoxy resin and cotton candy were used to form the phantoms with microchannels. The size of the channels was measured via microscopy and the proportion of the void volume (PVV) was calculated. The phantoms were placed in contrast agent solutions of different concentrations and scanned in μCT. The mean CT numbers of the phantoms were calculated with the Amira software and displayed as a function of the determined PVV and the contrast agent concentration (CAC). The fabricated microchannels had the size of biological capillaries (diameter: 5 µm to 15 µm) and the phantoms showed a microchannel density of 5 to15 microchannels per mm2. With an increasing CAC, the CT numbers increased significantly. Additionally, the phantoms with a higher PVV also had a higher CT number. The CT numbers and the PVV correlated moderately together, but significantly. The slope of the regression line increased with an increasing CAC.

Keywords: capillary phantoms; contrast enhanced; epoxy resin; imaging (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
http://vetmed.agriculturejournals.cz/doi/10.17221/100/2020-VETMED.html (text/html)
http://vetmed.agriculturejournals.cz/doi/10.17221/100/2020-VETMED.pdf (application/pdf)
free of charge

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:caa:jnlvet:v:67:y:2022:i:7:id:100-2020-vetmed

DOI: 10.17221/100/2020-VETMED

Access Statistics for this article

Veterinární medicína is currently edited by Ing. Helena Smolová Ph.D.

More articles in Veterinární medicína from Czech Academy of Agricultural Sciences
Bibliographic data for series maintained by Ivo Andrle ().

 
Page updated 2025-03-19
Handle: RePEc:caa:jnlvet:v:67:y:2022:i:7:id:100-2020-vetmed