EconPapers    
Economics at your fingertips  
 

Assessment of the accuracy of patient-specific drilling guides for cervical (C5-C6) and lumbar (L4-L5) vertebrae in cats

Costa Rc, Moraes Gg, Ferreira Rg, Neto Rb, M Nobile, Rocha Tass, Barros Lp, Minto Bw and Dias Lggg
Additional contact information
Costa Rc: Department of Veterinary Medicine and Veterinary Surgery, State University "Júlio de Mesquita Filho"/UNESP, Jaboticabal, SP, Brazil
Moraes Gg: Department of Veterinary Medicine and Veterinary Surgery, State University "Júlio de Mesquita Filho"/UNESP, Jaboticabal, SP, Brazil
Ferreira Rg: Department of Veterinary Medicine and Veterinary Surgery, State University "Júlio de Mesquita Filho"/UNESP, Jaboticabal, SP, Brazil
Neto Rb: Department of Veterinary Medicine and Veterinary Surgery, State University "Júlio de Mesquita Filho"/UNESP, Jaboticabal, SP, Brazil
M Nobile: Department of Veterinary Medicine and Veterinary Surgery, State University "Júlio de Mesquita Filho"/UNESP, Jaboticabal, SP, Brazil
Rocha Tass: Federal University of Jataí, UFJ, Jataí, GO, Brazil
Barros Lp: Department of Veterinary Medicine and Veterinary Surgery, State University "Júlio de Mesquita Filho"/UNESP, Jaboticabal, SP, Brazil
Minto Bw: Department of Veterinary Medicine and Veterinary Surgery, State University "Júlio de Mesquita Filho"/UNESP, Jaboticabal, SP, Brazil
Dias Lggg: Department of Veterinary Medicine and Veterinary Surgery, State University "Júlio de Mesquita Filho"/UNESP, Jaboticabal, SP, Brazil

Veterinární medicína, 2025, vol. 70, issue 1, 11-19

Abstract: Ten sets of vertebral biomodels and the corresponding drilling guides were created to evaluate the implantation accuracy in the cervical (C5-C6) and lumbar (L4-L5) vertebrae of cats. Smooth pins were implanted using the guides on the right side of five randomly assigned biomodel sets and on the left side of the remaining sets, with the contralateral side undergoing freehand implantation. Subsequently, a new tomographic study was conducted to measure the implantation angles. The pre-implantation angles were compared with the post-implantation angles between the techniques and among the sets. The guide-assisted implantation exhibited a lower dispersion compared to the freehand technique, with coefficients of variation of -1.95 and 48.9 in the cervical vertebrae and 1.98 and 9.39 in the lumbar vertebrae, respectively. However, no statistical difference was observed between the pre- and post-implantation angles, nor when comparing the vertebral segments (P > 0.05). Under the study conditions, the use of the guide failed to result in more accurate implantations in the C5-C6 and L4-L5 vertebral biomodels of cats.

Keywords: iatrogenic disease; neurosurgery; three-dimensional printing; vertebral body (search for similar items in EconPapers)
Date: 2025
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
http://vetmed.agriculturejournals.cz/doi/10.17221/73/2024-VETMED.html (text/html)
http://vetmed.agriculturejournals.cz/doi/10.17221/73/2024-VETMED.pdf (application/pdf)
free of charge

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:caa:jnlvet:v:70:y:2025:i:1:id:73-2024-vetmed

DOI: 10.17221/73/2024-VETMED

Access Statistics for this article

Veterinární medicína is currently edited by Ing. Helena Smolová Ph.D.

More articles in Veterinární medicína from Czech Academy of Agricultural Sciences
Bibliographic data for series maintained by Ivo Andrle ().

 
Page updated 2025-03-19
Handle: RePEc:caa:jnlvet:v:70:y:2025:i:1:id:73-2024-vetmed