EconPapers    
Economics at your fingertips  
 

Energy Optimization of Industrial Steam Boiler using Energy Performance Indicator

Guillermo Valencia Ochoa, Jhan Piero Rojas and Juan Campos Avella
Additional contact information
Guillermo Valencia Ochoa: Mechanical Engineering Program, Faculty of Engineering, Grupo de Investigaci n en Gesti n Eficiente de la Energia-ka , Universidad del Atl ntico, Carrera 30 N mero 8-49, Puerto Colombia 081007, Atl ntico, Colombia,
Jhan Piero Rojas: Faculty of Engineering, Universidad Francisco de Paula Santander, #0-a Avenida Gran Colombia No. 12E-96, C cuta, Norte de Santander, Colombia.
Juan Campos Avella: Mechanical Engineering Program, Faculty of Engineering, Grupo de Investigaci n en Gesti n Eficiente de la Energia-ka , Universidad del Atl ntico, Carrera 30 N mero 8-49, Puerto Colombia 081007, Atl ntico, Colombia,

International Journal of Energy Economics and Policy, 2019, vol. 9, issue 6, 109-117

Abstract: This article shows the application of an energy management system and the calculation of energy efficiency indicators to a pyrotubular boiler, following the guidelines of the ISO50001 standard. The actual energy consumption indicators, the theoretical consumption index, the energy baseline and the efficiency index 100 were evaluated based on gas consumption and steam production data. As for the savings measure, a 20% reduction in gas consumption can be achieved by reducing the operational variability equivalent to 186,633 m3/month, thereby achieving a monthly savings of $70,920,717 COP and a large reduction in natural gas equivalent to a reduction in CO2 emissions (1,318,739.05 kg CO2/month). Also, the purges currently recorded in the boiler are higher than the recommended value for this equipment, and the excess air released varies between 6% and 11%, increasing the losses due to sensible heat. Three main implementations were applied to improve the energy performance of the steam boiler. The first saving implementation was the reduction of the generation pressure from 250 to 180 psig, achieving a lower gas temperature with a reduction of heat losses from the boiler, pipes and steam leakage losses, achieving a saving of 2% of the average natural gas consumption. The second implementation was the automation of the boiler purges, in accordance with the recommended value UNE-9075/85, achieving a total saving of 0.66%, and the third measurement allows on-line correction of the combustion air by direct measurement of O2, which maintains the measured oxygen value at 3%, which is the recommended value. With this practical and novel method energy performance indicator on the boiler, was increased the performance of the equipment, as well as the production costs and environmental impact reduction.

Keywords: Energy Optimization; Steam Boiler; Energy Performance Indicator; ISO 50001 Standard. (search for similar items in EconPapers)
JEL-codes: Q42 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.econjournals.com/index.php/ijeep/article/download/8188/4639 (application/pdf)
https://www.econjournals.com/index.php/ijeep/article/view/8188/4639 (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eco:journ2:2019-06-14

Access Statistics for this article

International Journal of Energy Economics and Policy is currently edited by Ilhan Ozturk

More articles in International Journal of Energy Economics and Policy from Econjournals
Bibliographic data for series maintained by Ilhan Ozturk ().

 
Page updated 2025-03-19
Handle: RePEc:eco:journ2:2019-06-14