Effect of the start–stop cycle of center-pivot towers on irrigation performance: Experiments and simulations
S. Ouazaa,
B. Latorre,
J. Burguete,
A. Serreta,
E. Playán,
R. Salvador,
P. Paniagua and
N. Zapata
Agricultural Water Management, 2015, vol. 147, issue C, 163-174
Abstract:
The simulation of center-pivot performance has been the subject of research efforts since the 1960s. Center-pivot models frequently use empirical equations relating pressure and sprinkler radial application pattern. Individual, stationary water application patterns are overlapped and the resulting water application is mapped in the field. Such models use constant tower angular velocity, neglecting the effect of tower alignment. In this work the discontinuous tower movement has been experimentally characterized and modelled, and a complete model has been developed by using a ballistic model of the center-pivot sprinklers considering nozzle diameter, operating pressure and wind speed. A detailed kinetic analysis of a four-tower commercial center-pivot was performed. Each tower was monitored using a high precision GPS, recording tower positions at high frequency. The experimental center-pivot was equipped with fixed spray plate sprinklers (FSPS). Five experimental center-pivot irrigation events were evaluated using catch-cans. The analysis of tower location data permitted to conclude that two key variables (linear speed and switching angle) showed normal distribution patterns. The center-pivot model was validated with catch-can data. Finally, the simulation tool was used to assess the effect of variable tower alignment quality, center-pivot travel speed and wind conditions on irrigation performance. Comparisons were performed in terms of radial, circular and total irrigation uniformity. Results indicate that the observed tower dynamics had no measurable effect on irrigation uniformity. Tower alignment quality started to be relevant when the switching angle lag was equal to or larger than 2°. In the conditions of this analysis, wind speed showed a clear effect on uniformity. As wind speed increased, uniformity first decreased and then increased. Further research is required to generalize these results to other center-pivot sizes and designs (sprinkler packages).
Keywords: Center-pivot towers alignment; Towers dynamics; Center-pivot irrigation performance; Sprinkler application patterns; Fixed spray plate sprinklers (search for similar items in EconPapers)
Date: 2015
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0378377414001632
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:agiwat:v:147:y:2015:i:c:p:163-174
DOI: 10.1016/j.agwat.2014.05.013
Access Statistics for this article
Agricultural Water Management is currently edited by B.E. Clothier, W. Dierickx, J. Oster and D. Wichelns
More articles in Agricultural Water Management from Elsevier
Bibliographic data for series maintained by Catherine Liu ().