A comprehensive stress indicator for evaluating plant water status in almond trees
Kelley Drechsler,
Isaya Kisekka and
Shrinivasa Upadhyaya
Agricultural Water Management, 2019, vol. 216, issue C, 214-223
Abstract:
This study evaluated a comprehensive plant water stress indicator that integrates the leaf temperature and the environmental conditions that can provide feedback on the plant response to irrigation scheduling. This quantity—Comprehensive Stress Indicator (CSI)—is based on the reformulation of the leaf energy balance equation. Specifically, CSI is the ratio of the temperature difference between a dry leaf (i.e., a leaf with a broken stem) and a live leaf (on the same tree) [i.e., Tdry-Tleaf] and the difference between the vapor pressure inside the stomatal cavity at saturation and the vapor pressure of the air at ambient temperature [i.e., es(TL)-e(TA)]. The required measurements to compute CSI include dry leaf temperature, live leaf temperature, relative humidity, and air temperature at the tree being monitored. In this study, all measurements were obtained using a sensor suite called the leaf monitor. Leaf monitors were connected to a wireless mesh network to communicate the data to a website. The leaf monitor included two thermal infrared sensors, one for the dry leaf and one for the live leaf, both of which were housed in the same unit with almost identical environmental conditions due to a diffusing hemispherical dome that enclosed these sensors. The CSI is a dynamic indicator with a value for every data sample collected. For a single indicator representing each day, the CSI was evaluated in two ways. First, the CSI was integrated with respect to time from 10 A.M. to 6 P.M. to obtain the Integrated Comprehensive Stress Indicator (ICSI). Second, the CSI was averaged from 1 P.M. to 3 P.M. to obtain the Average Comprehensive Stress Indicator (ACSI). Both ICSI and ACSI were compared to other stress indicators, including the existing Crop Water Stress Index (CWSI) and Integrated Degrees Above Non-Stressed (IDANS). Results show that ICSI and ACSI are satisfactorily correlated with midday stem water potential (SWP). The ICSI and ACSI indicators may be more convenient than other stress indicators because they require measurements only at the tree being monitored.
Keywords: Infrared thermometry; Deficit irrigation; Stem water potential; Crop water stress index; Integrated degrees above non-stressed (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0378377418313763
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:agiwat:v:216:y:2019:i:c:p:214-223
DOI: 10.1016/j.agwat.2019.02.003
Access Statistics for this article
Agricultural Water Management is currently edited by B.E. Clothier, W. Dierickx, J. Oster and D. Wichelns
More articles in Agricultural Water Management from Elsevier
Bibliographic data for series maintained by Catherine Liu ().