Reconstruction Algorithm of Calibration Map for RPT Techniques in Quadrilateral Bubble Column Reactor Using MCNPX Code
Mohd Amirul Syafiq Mohd Yunos,
Mark Dennis Anak Usang,
Hanafi Ithnin,
Siti Aslina Hussain,
Hamdan Mohamed Yusoff and
Susan Sipaun
Additional contact information
Mohd Amirul Syafiq Mohd Yunos: Plant Assessment Technology Group, Industrial Technology Division, Malaysian Nuclear Agency, Kajang, Selangor
Mark Dennis Anak Usang: Reactor Technology Centre, Malaysian Nuclear Agency, Kajang, Selangor
Hanafi Ithnin: Plant Assessment Technology Group, Industrial Technology Division, Malaysian Nuclear Agency, Kajang, Selangor,
Siti Aslina Hussain: Department of Chemical and Environmental Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang
Hamdan Mohamed Yusoff: Department of Chemical and Environmental Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang
Susan Sipaun: Plant Assessment Technology Group, Industrial Technology Division, Malaysian Nuclear Agency, Kajang, Selangor
European Journal of Engineering and Technology Research, 2018, vol. 3, issue 1, 20-27
Abstract:
Radioactive Particle Tracking (RPT) is non-invasive evaluation technique capable of visualising and tracking the motion of the identified phase in bubble column reactor. The single radioactive particle emits ?-ray, and its movement in the column is tracked with the aid of arrays radiation detectors. In this study, Monte Carlo approach was programmed to reconstruct the particle tracer position so-called calibration map. The iterative reconstruction algorithms is used to generate and calculate the 2600 coordinates of calibration map from the number of photon counts from the ten NaI scintillation detectors. To validate the simulation precision, a spiral trajectory of radioactive particle inside the bubble column region consist of 84 grid point locations of the particle were applied. Calibration algorithm was developed for radioactive isotopes Au-198 and Sc-46 particle position verification and determination of statistical uncertainty from the introduction of a various number of primary photon emission. The result of the studies proved that higher number of particles used in the algorithm for position reconstruction gives more accuracy and we found that the Sc-46 obtain more accurate calculation and shows low statistical level than Au-198 particle. The outcome of this simulation based on random sampling from Monte Carlo N-Particle Extended (MCNPX) demonstrated that the calibration map could successfully be implemented in RPT technique to observe the dynamic movement of radioactive particle which represents the tracked media in the quadrilateral bubble column.
Keywords: Non-Invasive Technique; Radioactive Particle Tracking; Reconstruction Algorithm; Radioactive Isotope; MCNPX code; Bubble Column Reactor (search for similar items in EconPapers)
Date: 2018
References: Add references at CitEc
Citations:
Downloads: (external link)
https://eu-opensci.org/index.php/ejeng/article/view/60583 Abstract page (text/html)
https://eu-opensci.org/index.php/ejeng/article/download/60583/11838 Full text (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:epw:ejeng0:v:3:y:2018:i:1:id:60583
DOI: 10.24018/ejeng.2018.3.1.583
Access Statistics for this article
More articles in European Journal of Engineering and Technology Research from European Open Science
Bibliographic data for series maintained by Support ().