Design and Simulation of Air Conditioning System in a Large Auditorium Based on Computational Fluid Dynamics
Rahaman Abu,
K. A. Oladejo,
A. O. Popoola,
K. T. Oriolowo and
K. M. Odunfa
Additional contact information
Rahaman Abu: Department of Mechanical Engineering, University of Ibadan, Nigeria
K. A. Oladejo: Department of Mechanical Engineering, Obafemi Awolowo University, Ile-Ife, Nigeria
A. O. Popoola: Department of Mechanical Engineering, University of Ibadan, Nigeria
K. T. Oriolowo: Department of Industrial and Production Engineering, University of Ibadan, Nigeria
K. M. Odunfa: Department of Mechanical Engineering, University of Ibadan, Nigeria
European Journal of Engineering and Technology Research, 2020, vol. 5, issue 9, 1117-1123
Abstract:
Air conditioning system is an indispensable part of buildings today. The cost of this system increases with the rise in energy consumption which poses a challenge as well as air distribution in large auditoria. Analysis of results can also be daunting when designing this system. The study focuses on designing an air conditioning system in a large auditorium, applying Computational Fluid Dynamics (CFD) and visualizing the result in a Virtual Reality (VR) environment. The 3-dimensional model of the 520-capacity Technology Lecture Theatre, University of Ibadan, Nigeria was drawn with Autodesk Revit and modified into the geometry applicable for Displacement Ventilation (DV) and Mixed Ventilation (MV) for ease of numerical analysis with ANSYS Fluent. The building model and simulation results were then imported into Unity software for visualization in VR. The DV achieved better thermal comfort and air distribution in the computer simulation. At a supply temperature of 292.15 K, the DV system was able to keep the auditorium temperature at about 296.50 K, while the MV system at a supply temperature of 289.15 K was only able to maintain the temperature at 295.40 K. The temperature profile showed that the lower region where the students were seated was colder in DV compared to MV by at least 3 K. The results were also observed from a convenient position in VR. This study, with the aid of CFD and VR, was able to establish that displacement ventilation design has better air flow, lower energy consumption and is efficient for an air conditioning system in a large auditorium.
Keywords: Computational Fluid Dynamics; Displacement Ventilation; Mixed Ventilation; Virtual Reality (search for similar items in EconPapers)
Date: 2020
References: Add references at CitEc
Citations:
Downloads: (external link)
https://eu-opensci.org/index.php/ejeng/article/view/62062 Abstract page (text/html)
https://eu-opensci.org/index.php/ejeng/article/download/62062/12493 Full text (application/pdf)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:epw:ejeng0:v:5:y:2020:i:9:id:62062
DOI: 10.24018/ejeng.2020.5.9.2062
Access Statistics for this article
More articles in European Journal of Engineering and Technology Research from European Open Science
Bibliographic data for series maintained by Support ().