EconPapers    
Economics at your fingertips  
 

Grey Relational Analysis for Insulation Condition Assessment of Power Transformers Based Upon Conventional Dielectric Response Measurement

Jiefeng Liu, Hanbo Zheng, Yiyi Zhang, Hua Wei and Ruijin Liao
Additional contact information
Jiefeng Liu: Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, China
Hanbo Zheng: Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, China
Yiyi Zhang: Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, China
Hua Wei: Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, China
Ruijin Liao: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China

Energies, 2017, vol. 10, issue 10, 1-16

Abstract: Conventional dielectric response measurement techniques, for instance, recovery voltage measurement (RVM), frequency domain spectroscopy (FDS) and polarization–depolarization current (PDC) are effective nondestructive insulation monitoring techniques for oil-impregnated power transformers. Previous studies have focused mainly on some single type of dielectric measurement method. However, the condition of oil paper insulation in transformer is affected by many factors, so it is difficult to predict the insulation status by means of a single method. In this paper, the insulation condition assessment is performed by grey relational analysis (GRA) technique after carefully investigating different dielectric response measurement data. The insulation condition sensitive parameters of samples with unknown insulation status are extracted from different dielectric response measurement data and then these are used to contrast with the standard insulation state vector models established in controlled laboratory conditions by using GRA technique for predicting insulation condition. The performance of the proposed approach is tested using both the laboratory samples and a power transformer to demonstrate that it can provide reliable and effective insulation diagnosis.

Keywords: recovery voltage measurement; polarization–depolarization current; frequency domain spectroscopy; grey relational analysis; oil-impregnated transformers (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (8)

Downloads: (external link)
https://www.mdpi.com/1996-1073/10/10/1526/pdf (application/pdf)
https://www.mdpi.com/1996-1073/10/10/1526/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:10:y:2017:i:10:p:1526-:d:114290

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-24
Handle: RePEc:gam:jeners:v:10:y:2017:i:10:p:1526-:d:114290