Partial Discharge of Needle-Plane Defect in Oil-Paper Insulation under AC and DC Combined Voltages: Developing Processes and Characteristics

Jiantao Sun, Xining Li, Lingyu Zhu, Shengchang Ji and Yanjie Cui
Additional contact information
Jiantao Sun: China Electric Power Research Institute, Beijing 100192, China
Xining Li: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
Lingyu Zhu: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
Shengchang Ji: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
Yanjie Cui: State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China

Energies, 2017, vol. 10, issue 11, 1-17

Abstract: Partial discharge (PD) behaviors of oil-paper insulation is distinctive in AC and DC combined electric fields in converter transformers from PD behaviors in pure AC or DC electric fields. The present study focuses on the PD developing processes and characteristics of oil-paper insulation systems with needle-plane defects under different AC/DC proportions. The degradation of oil-paper insulation can be accelerated by PD pulses incurred by needle-plane defects. AC-DC combined voltages are applied to the needle-plane defect model simultaneously in the established experimental platform, and the proportions of AC/DC voltages are decided according to the cases in actual converter transformers. The developing processes from the initiation of partial discharge until final breakdown were observed for each AC/DC proportion. PD parameters and patterns were acquired by a detector using the pulse current method. The test results indicate that the inception and breakdown voltages increase with the increase of the DC component in AC-DC combined voltages. However, pulse repetition rate and amplitude of PD shows a descending trend when AC/DC proportion decreases. Meanwhile, the PD recurrence rate in the phase between 180° and 360° becomes higher than that in the phase between 0° and 180° at the initial stage as the DC proportion increases; high-amplitude discharges mainly occur in the phase range between 180° and 360° when the pressboard is close to breakdown. The current study is useful in further research on fault diagnosis in converter transformers.

Keywords: oil-paper insulation; converter transformer; partial discharge (PD); needle-plane defect; AC/DC proportion (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/10/11/1759/pdf (application/pdf)
https://www.mdpi.com/1996-1073/10/11/1759/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:10:y:2017:i:11:p:1759-:d:117275

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-24
Handle: RePEc:gam:jeners:v:10:y:2017:i:11:p:1759-:d:117275