Study on Quantitative Correlations between the Ageing Condition of Transformer Cellulose Insulation and the Large Time Constant Obtained from the Extended Debye Model
Yiyi Zhang,
Jiefeng Liu,
Hanbo Zheng,
Hua Wei and
Ruijin Liao
Additional contact information
Yiyi Zhang: Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, China
Jiefeng Liu: Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, China
Hanbo Zheng: Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, China
Hua Wei: Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, China
Ruijin Liao: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China
Energies, 2017, vol. 10, issue 11, 1-17
Abstract:
Polarization-depolarization current (PDC) measurements are now being used as a diagnosis tool to predict the ageing condition of transformer oil-paper insulation. Unfortunately, it is somewhat difficult to obtain the ageing condition of transformer cellulose insulation using the PDC technique due to the variation in transformer insulation geometry. In this literature, to quantify the ageing condition of transformer cellulose insulation using the PDC technique, we firstly designed a series of experiments under controlled laboratory conditions, and then obtained the branch parameters of an extended Debye model using the technique of curve fitting the PDC data. Finally, the ageing effect and water effect on the parameters of large time constant branches were systematically investigated. In the present paper, it is observed that there is a good exponential correlation between large time constants and degree of polymerization (DP). Therefore, the authors believe that the large time constants may be regard as a sensitive ageing indicator and the nice correlations might be utilized for the quantitative assessment of ageing condition in transformer cellulose insulation in the future due to the geometry independence of large time constants. In addition, it is found that the water in cellulose pressboards has a predominant effect on large time constants.
Keywords: polarization-depolarization current; transformer cellulose insulation; ageing effect; water effect; quantitative correlation; large time constant (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (12)
Downloads: (external link)
https://www.mdpi.com/1996-1073/10/11/1842/pdf (application/pdf)
https://www.mdpi.com/1996-1073/10/11/1842/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:10:y:2017:i:11:p:1842-:d:118444
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().