Anti-Freezing Mechanism Analysis of a Finned Flat Tube in an Air-Cooled Condenser
Yonghong Guo,
Tongrui Cheng,
Xiaoze Du and
Lijun Yang
Additional contact information
Yonghong Guo: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Ministry of Education, Beijing 102206, China
Tongrui Cheng: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Ministry of Education, Beijing 102206, China
Xiaoze Du: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Ministry of Education, Beijing 102206, China
Lijun Yang: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Ministry of Education, Beijing 102206, China
Energies, 2017, vol. 10, issue 11, 1-21
Abstract:
In cold winter weather, the air-cooled condensers (ACCs) face serious freezing risks, especially with part load of the power generating unit. Therefore, it is of benefit to investigate the heat transfer process between the turbine exhaust steam and cooling air, by which the freezing mechanism of the finned tube bundles can be revealed. In this work, the flow and heat transfer models of the cooling air coupling with the circulating water, are developed and numerically simulated for the anti-freezing analysis on basis of the finned tube bundles of the condenser cell. The local air-side heat transfer coefficient, condensate film development, and non-condensable gas development are obtained and analyzed in detail. The results show that, the most freezing risk happens at the fin base due to the highest air-side cooling capacity, besides the windward velocity, ambient temperature and turbine back pressure all determine the freezing risk with the constant inlet flow rate of the non-condensable gas. Furthermore, increasing fin thickness and decreasing fan rotating speed are the most effective anti-freezing measures. Additionally, increasing turbine back pressure can also be adopted to avoid ACC freezing, however the adjustment of outlet steam-air flow is not recommended.
Keywords: finned flat tube; condensation; anti-freezing; critical anti-freezing outlet mixture flow (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/10/11/1872/pdf (application/pdf)
https://www.mdpi.com/1996-1073/10/11/1872/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:10:y:2017:i:11:p:1872-:d:118965
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().