Sensorless Control of Late-Stage Offshore DFIG-WT with FSTP Converters by Using EKF to Ride through Hybrid Faults

Wei Li, Gengyin Li, Kai Ni, Yihua Hu and Xinhua Li
Additional contact information
Wei Li: State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Changping District, Beijing 102206, China
Gengyin Li: State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Changping District, Beijing 102206, China
Kai Ni: Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ, UK
Yihua Hu: Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ, UK
Xinhua Li: Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ, UK

Energies, 2017, vol. 10, issue 12, 1-26

Abstract: A hybrid fault scenario in a late-stage offshore doubly-fed induction generator (DFIG)-based wind turbine (DFIG-WT) with converter open-circuit fault and position sensor failure is investigated in this paper. An extended Kalman filter (EKF)-based sensorless control strategy is utilized to eliminate the encoder. Based on the detailed analysis of the seventh-order dynamic state space model of DFIG, along with the input voltage signals and measured current signals, the EKF algorithm for DFIG is designed to estimate the rotor speed and position. In addition, the bridge arm open circuit in the back-to-back (BTB) power converter of DFIG is taken as a commonly-encountered fault due to the fragility of semiconductor switches. Four-switch three-phase (FSTP) topology-based fault-tolerant converters are employed for post-fault operation by considering the minimization of switching losses and reducing the circuit complexity. Moreover, a simplified space vector pulse width modulation (SVPWM) technique is proposed to reduce the computational burden, and a voltage balancing scheme is put forward to increase the DC-bus voltage utilization rate. Simulation studies are carried out in MATLAB/Simulink2017a (MathWorks, Natick, MA, USA) to demonstrate the validity of the proposed hybrid fault-tolerant strategy for DFIG-WT, with the wind speed fluctuation, measurement noises and grid voltage sag taken into consideration.

Keywords: hybrid fault; doubly-fed induction generator; extended Kalman filter; sensorless control; back-to-back power converter; four-switch three-phase converter (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/10/12/1939/pdf (application/pdf)
https://www.mdpi.com/1996-1073/10/12/1939/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:10:y:2017:i:12:p:1939-:d:120084

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-24
Handle: RePEc:gam:jeners:v:10:y:2017:i:12:p:1939-:d:120084