EconPapers    
Economics at your fingertips  
 

Analysis of Power Loss and Improved Simulation Method of a High Frequency Dual-Buck Full-Bridge Inverter

Zhun Meng, Yi-Feng Wang, Liang Yang and Wei Li
Additional contact information
Zhun Meng: School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072, China
Yi-Feng Wang: School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072, China
Liang Yang: School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072, China
Wei Li: School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072, China

Energies, 2017, vol. 10, issue 3, 1-18

Abstract: A high frequency dual-buck full-bridge inverter for small power renewable energy application is proposed in this paper. A switching frequency of 400 kHz is achieved with the adoption of the SiC power device. A two-pole two-zero (2P2Z) compensator is employed in the outer voltage loop to generate the current reference for inner current loop. A 3P3Z compensator is adopted in the inner current loop to track the current reference. A systematic way for calculating the losses of high frequency inverter is presented, and the losses of the components are thoroughly analyzed. The turn-on and turn-off procedures of the inverter are discussed in detail. The losses caused by high frequency are calculated accurately, and the loss distribution is established as well. The procedure of the loss analysis gives a practical example for calculating the loss of similar type inverters. Moreover, deviation between pulse width modulation (PWM) control signal and switching response in high frequency switching is thoroughly analyzed. The influence of deviation is verified by designed experiment. Hence, a compensation method is proposed in order to minimize the influence. The compensation effect is validated by experiment and simulation. Finally, a 1-kW prototype is built to verify the feasibility of the theoretical analyses. The grid-connected maximum output power experiment is completed at 1 kW with the efficiency of 96.1% and the total harmonic distortion (THD) of 1.8%. The comparison experiments of power loss between Si and SiC power devices are carried out. The experiment results confirm the loss calculation method to be valid.

Keywords: SiC power device; grid-connected generation; dual-buck inverter; high frequency conversion; loss analysis; simulation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (6)

Downloads: (external link)
https://www.mdpi.com/1996-1073/10/3/311/pdf (application/pdf)
https://www.mdpi.com/1996-1073/10/3/311/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:10:y:2017:i:3:p:311-:d:92292

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-24
Handle: RePEc:gam:jeners:v:10:y:2017:i:3:p:311-:d:92292