EconPapers    
Economics at your fingertips  
 

A Highly Relevant Method for Incorporation of Shunt Connected FACTS Device into Multi-Machine Power System to Dampen Electromechanical Oscillations

Le Van Dai, Doan Duc Tung and Le Cao Quyen
Additional contact information
Le Van Dai: Institute of Research and Development, Duy Tan University, Da Nang 550000, Vietnam
Doan Duc Tung: Department of Engineering and Technology, Quy Nhon University, Binh Dinh 820000, Vietnam
Le Cao Quyen: Department for Management of Science and Technology Development, Ton Duc Thang University, Ho Chi Minh City 700000, Vietnam

Energies, 2017, vol. 10, issue 4, 1-27

Abstract: A number of techniques have been proposed to dampen the power system oscillations in the electric power systems. Flexible alternating current transmission system (FACTS) devices are becoming one of them. Among the FACTS family, the static synchronous compensator (STATCOM), a shunt connected FACTS device, has been widely used to provide smooth and rapid steady state, limit transient voltage, and improve the power system stability and performance by absorbing or injecting reactive power. However, the influence ability depends on its placement, control signal, and place of receiving-signal in the network. In order to satisfy these issues, this paper proposes a method for optimal setting and signal position of the STATCOM into the multi-machine power systems with the aim for damping the electromechanical oscillations. This method is developed from the energy approach based on Gramian matrices considering multiple tasks on the Lyapunov equation, in which the observability Gramian matrix is used to seek an optimal location for STATCOM placement. The another is the controllability one used to determine the best local input signal placement that is chosen as a feedback signal for the power oscillation damping (POD) of STATCOM. In addition, the Krylov-based model reduction method is introduced to shorten the calculation time. The proposed method has been verified on the IEEE 24-bus system by analyzing the small-signal stability to search several feasible placements, and then the transient stability is analyzed to compare and determine an optimal placement through testing various cases. The obtained result is also compared with other optimal method.

Keywords: electromechanical oscillations; optimal placement; Gramian matrix; static synchronous compensator (STATCOM); multi-machine power systems (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/10/4/482/pdf (application/pdf)
https://www.mdpi.com/1996-1073/10/4/482/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:10:y:2017:i:4:p:482-:d:94950

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-24
Handle: RePEc:gam:jeners:v:10:y:2017:i:4:p:482-:d:94950