Study on the Characteristic Decomposition Components of DC SF 6 -Insulated Equipment under Positive DC Partial Discharge
Min Liu,
Ju Tang,
Xin Liu,
Qiang Yao and
Yulong Miao
Additional contact information
Min Liu: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing 400000, China
Ju Tang: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing 400000, China
Xin Liu: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing 400000, China
Qiang Yao: Chongqing Power Company, Chongqing 400000, China
Yulong Miao: Chongqing Power Company, Chongqing 400000, China
Energies, 2017, vol. 10, issue 5, 1-13
Abstract:
Pulses with different amplitudes occur when an inner partial discharge fault exists in SF 6 -gas-insulated DC high-voltage electrical equipment. SF 6 decomposes following complex physical and chemical processes. Discussing and quantifying the mathematical relationship of pulse discharge quantities to SF 6 decomposition component characteristics is helpful to evaluate and predict the insulation fault severity and development trends in SF 6 -insulated DC equipment. Numerous simulation experiments on SF 6 decomposition under positive DC partial discharge were performed on a needle-plane model. The DC partial discharge quantities of pulses are obtained, and decomposition characteristics based on the mechanism of SF 6 decomposition are analyzed. Results show that generation, effective generation rate and concentration ratio c(SO 2 F 2 + SOF 4 )/c(SOF 2 + SO 2 ) of components increase with partial discharge severity, and the first two act in the following order: SOF 4 > SOF 2 > SO 2 F 2 > SO 2 > CF 4 when the discharge quantity level is higher than 238,957 pC. Finally, a coefficient matrix illustrates the mathematical effects of pulses with different discharge quantities on different SF 6 decomposition components. The pulses whose discharge quantity is higher than 50 pC have obvious promotion effects on the formation of decomposition components, whereas the pulses whose discharge quantity lower than 50 pC decrease the positive promotion effects that large discharge pulses have on decomposition components. The higher the effective generation rates are, the greater the partial discharge severity is, and their change laws provide a new method to evaluate and predict insulation fault severity and development trends in DC SF 6 -insulated equipment with high reliability and detection stability.
Keywords: SF 6; DC partial discharge; discharge quantity; decomposition component; generation rate (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1996-1073/10/5/640/pdf (application/pdf)
https://www.mdpi.com/1996-1073/10/5/640/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:10:y:2017:i:5:p:640-:d:97665
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().