EconPapers    
Economics at your fingertips  
 

Research on Capacitance Current Compensation Scheme of Current Differential Protection of Complex Four-Circuit Transmission Lines on the Same Tower

Cui Tang, Xianggen Yin and Zhe Zhang
Additional contact information
Cui Tang: State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
Xianggen Yin: State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
Zhe Zhang: State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China

Energies, 2017, vol. 10, issue 7, 1-16

Abstract: Current differential protection is the main protection of transmission lines which include multi-circuit lines on the same tower, and whose sensitivity and reliability of differential protection is mainly affected by the distributed capacitive current. For the four-circuit line on the same tower, due to the influence of coupling between the loop road, the distributed capacitance current increases significantly when compared with ordinary lines, affecting the sensitivity of the current differential protection, especially for different voltage levels throughout the four-circuit lines on the same tower. The relationship of the electrostatic coupling between the circuits is more complex, and increases the difficulty of the compensating the distributed capacitance current. This paper is based on the electrostatic coupling principle of four-circuit lines on the same tower, establishes the distributed parameter model of four-circuit transmission lines on the same tower, and discusses the effect of circuit operation mode on the compensation of capacitance current differential protection when different faults occur on the complex four-circuit transmission lines on the same tower. A new compensation scheme suitable for capacitive current compensation is proposed. Simulation results show that this capacitive current compensation scheme can effectively improve the performance of current differential protection.

Keywords: current differential protection; complex tower; operation mode; capacitance current compensation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/10/7/1071/pdf (application/pdf)
https://www.mdpi.com/1996-1073/10/7/1071/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:10:y:2017:i:7:p:1071-:d:105645

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-24
Handle: RePEc:gam:jeners:v:10:y:2017:i:7:p:1071-:d:105645