Nonlinear Controllers Based on Exact Feedback Linearization for Series-Compensated DFIG-Based Wind Parks to Mitigate Sub-Synchronous Control Interaction
Penghan Li,
Jie Wang,
Linyun Xiong and
Fei Wu
Additional contact information
Penghan Li: School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
Jie Wang: School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
Linyun Xiong: School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
Fei Wu: School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
Energies, 2017, vol. 10, issue 8, 1-16
Abstract:
The increasing penetration of wind power in the grid has driven the integration of wind farms with power systems that are series-compensated to enhance power transfer capability and dynamic stability. This may lead to sub-synchronous control interaction (SSCI) problems in series-compensated doubly-fed induction generator (DFIG)-based wind farms. To mitigate SSCI, nonlinear controllers based on exact feedback linearization (EFL) are proposed in this paper. Before deriving the control laws, the exact feedback linearizability of the studied system is scrutinized. Frequency scanning analysis is employed to test the designed EFL controllers. Moreover, the performance of the EFL controllers is compared to that of classical proportional-integral (PI) controllers. A series-compensated 100 MW DFIG-based wind park is utilized to assess the performance of the designed controllers through the alleviation of sub-synchronous resonance. Analyses of the studied system reveal that the resistance is negative under sub-synchronous frequency conditions, whereas the reactance becomes negative at approximately 44 Hz. The designed EFL controllers effectively alleviate SSCI and result in positive reactance and resistance values within the whole sub-synchronous frequency range. The results from the frequency scanning method are also validated through the time domain simulation and the eigenvalue analysis.
Keywords: doubly-fed induction generator; sub-synchronous control interaction; exact feedback linearization; frequency scanning analysis (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View complete reference list from CitEc
Citations: View citations in EconPapers (3)
Downloads: (external link)
https://www.mdpi.com/1996-1073/10/8/1182/pdf (application/pdf)
https://www.mdpi.com/1996-1073/10/8/1182/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:10:y:2017:i:8:p:1182-:d:107721
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().