EconPapers    
Economics at your fingertips  
 

Spectrometer-Based Line-of-Sight Temperature Measurements during Alkali-Pulverized Coal Combustion in a Power Station Boiler

Weijie Yan, Yunqi Ya, Feng Du, Hao Shao and Peitao Zhao
Additional contact information
Weijie Yan: School of Electrical and Power Engineering, China University of Mining and Technology, No.1, Daxue Road, Xuzhou 221116, China
Yunqi Ya: School of Electrical and Power Engineering, China University of Mining and Technology, No.1, Daxue Road, Xuzhou 221116, China
Feng Du: Huadian Power International Corporation Limited Zouxian power plant, Tangcun town, Zhoucheng 273500, China
Hao Shao: School of Safety Engineering, China University of Mining and Technology, No.1, Daxue Road, Xuzhou 221116, China
Peitao Zhao: School of Electrical and Power Engineering, China University of Mining and Technology, No.1, Daxue Road, Xuzhou 221116, China

Energies, 2017, vol. 10, issue 9, 1-14

Abstract: A portable spectrometer system that simultaneously measures the temperature, emissivity, and radiation intensity of an alkali metal was used in a 1000 MW coal-fired power plant boiler furnace. A calibrated fiber-optic spectrometer system was applied to obtain the radiation intensity of the flame. A simple method based on polynomial fitting was used to separate the continuous baseline from the measured flame spectra that contained both continuous and discontinuous bands. Nine synthetic spectra that included the baseline, noise, and three simulated discontinuous bands based on a Gaussian function were created to test the accuracy of the separation method. The accuracy of the estimated continuous baseline was evaluated by the goodness-of-fit coefficient quality metric. The results indicated good spectral matching for the selected profiles. The soot emissivity model by Hottel and Broughton was employed to calculate temperature and emissivity. The influence of discontinuous emission spectra on the temperature and emissivity calculations was evaluated. The results showed that the maximum difference of the measurement points of the calculated temperature was only 6 K and that the relative difference in emissivity among the measurement points was less than 5%. In addition, a comparison between the actual intensity of the alkali metal and the calculated temperature indicated that the change in the radiation intensity of the alkali metal followed the trend of the calculated temperature. This study serves as a preliminary investigation for measuring gas-phase alkali metal concentrations in a furnace.

Keywords: temperature measurement; flame spectrum; emissivity; alkali metal emission (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/1996-1073/10/9/1375/pdf (application/pdf)
https://www.mdpi.com/1996-1073/10/9/1375/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:10:y:2017:i:9:p:1375-:d:111485

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-24
Handle: RePEc:gam:jeners:v:10:y:2017:i:9:p:1375-:d:111485