EconPapers    
Economics at your fingertips  
 

Constant-Frequency Model Predictive Direct Power Control for Fault-Tolerant Bidirectional Voltage-Source Converter with Balanced Capacitor Voltage

Shiyang Hu, Guorong Liu, Nan Jin and Leilei Guo
Additional contact information
Shiyang Hu: College of Electrical and Information Engineering, Hunan University, Changsha 410082, China
Guorong Liu: College of Electrical Engineering and Information Engineering, Hunan Institute of Engineering, Xiangtan 411104, China
Nan Jin: College of Electrical and Information Engineering, Zhengzhou University of Light Industry, Zhengzhou 450002, China
Leilei Guo: College of Electrical and Information Engineering, Zhengzhou University of Light Industry, Zhengzhou 450002, China

Energies, 2018, vol. 11, issue 10, 1-20

Abstract: This paper proposes a constant-frequency model predictive direct power control (CF-MPDPC) method for a fault-tolerant bidirectional voltage-source converter (BVSC). The method can enhance the reliability and fault-tolerant operation capability of BVSCs in the condition of bridge-arm fault. Through the analysis of a fault-tolerant three-phase four-switch (TPFS) structure and the voltage vectors in the αβ stationary frame, the predictive power model and DC-link midpoint voltage offset suppression are established. According to model-predictive theory, fault-tolerant TPFS, and multivector control, the CF-MPDPC method for fault-tolerant BVSC is presented. The method realizes direct power control based on three output vectors with constant frequency, which can track the optimal vector more accurately and reduce current harmonics. Furthermore, the balanced control of DC-link capacitor voltages is also achieved by adding the term of DC-link midpoint voltage offset into the cost function. The balanced capacitor voltages protect the converter against the second faults caused by over-voltage operation of electrolytic capacitor. The simulation and experimental results prove that the fault-tolerant BVSC controlled by proposed method can maintain the continuous operation when the switching devices have fault. Low current harmonic content and stable output power exhibit good reliability and dynamic performance of the proposed CF-MPDPC for a fault-tolerant BVSC with a phase fault.

Keywords: bidirectional voltage source converter; fault-tolerant; model predictive control; constant frequency; three-phase four-switch; direct power control (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/10/2692/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/10/2692/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:10:p:2692-:d:174527

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:10:p:2692-:d:174527