EconPapers    
Economics at your fingertips  
 

Power Factor Corrector with Bridgeless Flyback Converter for DC Loads Applications

Sheng-Yu Tseng, Po-Jui Huang and Dong-Heng Wu
Additional contact information
Sheng-Yu Tseng: Department of Electircal Engineering, Chang Gung University, Tao-Yuan 33302, Taiwan
Po-Jui Huang: Department of Electircal Engineering, Chang Gung University, Tao-Yuan 33302, Taiwan
Dong-Heng Wu: Department of Electircal Engineering, Chang Gung University, Tao-Yuan 33302, Taiwan

Energies, 2018, vol. 11, issue 11, 1-20

Abstract: Since power systems with a DC distribution method has many advantages, such as conversion efficiency increase of about 5–10%, cost reducing by about 15–20% and so on, the AC distribution power system will be replaced by a DC distribution one. This paper presents a DC load power system for a DC distribution application. The proposed power system includes two converters: DC/DC converter with battery source and power factor corrector (PFC) with a line source to increase the reliability of the power system when renewable energy or energy storage equipment are adopted. The proposed PFC adopts a bridgeless flyback converter to achieve power factor correction for supplying power to DC loads. When the bridgeless flyback converter is used to achieve PFC, it needs two transformers to process positive and negative half periods, respectively. In order to increase conversion efficiency, the flyback one can add two sets of the active clamp circuit to recover energies stored in leakage inductances of transformers in the converter. Therefore, the proposed bridgeless flyback converter can not only integrate two transformers into a single transformer, but also share a clamp capacitor to achieve energy recovery of leakage inductances and to operate switches with zero-voltage switching (ZVS) at the turn-on transition. With this approach, the proposed converter can increase conversion efficiency and decrease component counts, where it results in a higher conversion efficiency, lower cost, easier design and so on. Finally, a prototype with a universal input voltage source (AC 90–265 V) under output voltage of 48 V and maximum output power of 300 W has been implemented to verify the feasibility of the proposed bridgeless flyback converter. Furthermore, the proposed power system can be operated at different cases among load power P L , output power P DC1 of DC/DC converter and output power P DC2 of the proposed PFC for supplying power to DC loads.

Keywords: bridgeless flyback converter; PFC; active clamp circuit; ZVS; DC distribution (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/11/3096/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/11/3096/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:11:p:3096-:d:181659

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:11:p:3096-:d:181659