EconPapers    
Economics at your fingertips  
 

Effectiveness Analysis and Temperature Effect Mechanism on Chemical and Electrical-Based Transformer Insulation Diagnostic Parameters Obtained from PDC Data

Hanbo Zheng, Jiefeng Liu, Yiyi Zhang, Yijie Ma, Yang Shen, Xiaochen Zhen and Zilai Chen
Additional contact information
Hanbo Zheng: Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, Guangxi, China
Jiefeng Liu: Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, Guangxi, China
Yiyi Zhang: Guangxi Key Laboratory of Power System Optimization and Energy Technology, Guangxi University, Nanning 530004, Guangxi, China
Yijie Ma: Shijiazhuang Power Supply Branch of State Grid Electric Power Company, Shijiazhuang 050000, Hebei, China
Yang Shen: Shijiazhuang Power Supply Branch of State Grid Electric Power Company, Shijiazhuang 050000, Hebei, China
Xiaochen Zhen: Shijiazhuang Power Supply Branch of State Grid Electric Power Company, Shijiazhuang 050000, Hebei, China
Zilai Chen: Shijiazhuang Power Supply Branch of State Grid Electric Power Company, Shijiazhuang 050000, Hebei, China

Energies, 2018, vol. 11, issue 1, 1-17

Abstract: The dielectric monitoring/diagnostic tool, such as Polarization and Depolarization Current (PDC) measurement, is now being widely applied to obtain the status of deteriorated transformers around the world. Nowadays, several works have reported that the chemical and electrical-based transformer insulation diagnostic parameters (absorption ratio, polarization index, paper conductivity, oil conductivity, insulation resistance, etc.) can be easily calculated from the PDC data. It is a fact that before using these parameters to obtain the status of deteriorated transformers, the power engineers should prudently investigate the effectiveness of these parameters. However, there are few papers that investigate the important issue. In addition, the understanding of temperature effect mechanism on these parameters should also be prudently studied. In the present work, we firstly prepare several oil-impregnated pressboard specimens with various insulation statuses by using a sequence of thermal ageing and moisture absorption experiments launched in the laboratory, and then the PDC measurement is performed to obtain the chemical and electrical-based transformer insulation diagnostic parameters. Finally, we systematically interpret the effectiveness and temperature effect mechanism on these chemical and electrical-based transformer insulation diagnostic parameters.

Keywords: dielectric monitoring/diagnostic tool; polarization and depolarization current (PDC); transformer; chemical and electrical-based transformer insulation diagnostic parameters; effectiveness; temperature effect mechanism (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (6)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/1/146/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/1/146/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:1:p:146-:d:125839

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:1:p:146-:d:125839