EconPapers    
Economics at your fingertips  
 

Impact of Heat Pump-Driven Liquid Desiccant Dehumidification on the Energy Performance of an Evaporative Cooling-Assisted Air Conditioning System

Jang-Hoon Shin, Joon-Young Park, Min-Suk Jo and Jae-Weon Jeong
Additional contact information
Jang-Hoon Shin: Department of Architectural Engineering, College of Engineering, Hanyang University, 222 Wangsimni-Ro, Seongdong-Gu, Seoul 04763, Korea
Joon-Young Park: Department of Architectural Engineering, College of Engineering, Hanyang University, 222 Wangsimni-Ro, Seongdong-Gu, Seoul 04763, Korea
Min-Suk Jo: Department of Architectural Engineering, College of Engineering, Hanyang University, 222 Wangsimni-Ro, Seongdong-Gu, Seoul 04763, Korea
Jae-Weon Jeong: Department of Architectural Engineering, College of Engineering, Hanyang University, 222 Wangsimni-Ro, Seongdong-Gu, Seoul 04763, Korea

Energies, 2018, vol. 11, issue 2, 1-21

Abstract: The main objective of this research is to investigate the energy performance enhancement obtained by applying a heat pump to a liquid desiccant and indirect and direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS). In conventional LD-IDECOAS operation, the boiler providing regeneration heat to the weak desiccant solution consumes most of the energy. In order to reduce the regeneration energy consumption in the LD-IDECOAS, a heat pump-integrated LD-IDECOAS (HPLD-IDECOAS) is suggested in this research. The heat pump reclaims waste heat from the absorber side of the system, and delivers the reclaimed heat to the regenerator side. Detailed energy simulations for both the LD-IDECOAS and HPLD-IDECOAS were conducted to analyze the energy saving potentiality of the proposed system over the conventional LD-IDECOAS. In both systems, it was assumed that a packed-bed type liquid desiccant unit with an aqueous solution of lithium chloride (LiCl) was used. In the proposed system, a heat pump with R-134a refrigerant was adopted. The results show that the proposed system was able to provide a 33% reduction in annual primary energy consumption compared with the conventional LD-IDECOAS. This significantly enhanced energy performance was mainly obtained through an 83% reduction in the gas energy consumed for regeneration of the desiccant solution in the proposed system by applying the heat pump.

Keywords: liquid desiccant system; evaporative cooling system; 100% outdoor air system; heat pump-driven liquid desiccant system; heat recovery (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (7)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/2/345/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/2/345/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:2:p:345-:d:130014

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:2:p:345-:d:130014