EconPapers    
Economics at your fingertips  
 

Impact of Demand Side Response on a Commercial Retail Refrigeration System

Ibrahim M. Saleh, Andrey Postnikov, Corneliu Arsene, Argyrios C. Zolotas, Chris Bingham, Ronald Bickerton and Simon Pearson
Additional contact information
Ibrahim M. Saleh: School of Engineering, University of Lincoln, Brayford Pool, Lincoln LN6 7TS, UK
Andrey Postnikov: School of Engineering, University of Lincoln, Brayford Pool, Lincoln LN6 7TS, UK
Corneliu Arsene: School of Engineering, University of Lincoln, Brayford Pool, Lincoln LN6 7TS, UK
Argyrios C. Zolotas: School of Engineering, University of Lincoln, Brayford Pool, Lincoln LN6 7TS, UK
Chris Bingham: School of Engineering, University of Lincoln, Brayford Pool, Lincoln LN6 7TS, UK
Ronald Bickerton: School of Engineering, University of Lincoln, Brayford Pool, Lincoln LN6 7TS, UK
Simon Pearson: School of Engineering, University of Lincoln, Brayford Pool, Lincoln LN6 7TS, UK

Energies, 2018, vol. 11, issue 2, 1-18

Abstract: The UK National Grid has placed increased emphasis on the development of Demand Side Response (DSR) tariff mechanisms to manage load at peak times. Refrigeration systems, along with HVAC, are estimated to consume 14% of the UK’s electricity and could have a significant role for DSR application. However, characterized by relatively low individual electrical loads and massive asset numbers, multiple low power refrigerators need aggregation for inclusion in these tariffs. In this paper, the impact of the Demand Side Response (DSR) control mechanisms on food retailing refrigeration systems is investigated. The experiments are conducted in a test-rig built to resemble a typical small supermarket store. The paper demonstrates how the temperature and pressure profiles of the system, the active power and the drawn current of the compressors are affected following a rapid shut down and subsequent return to normal operation as a response to a DSR event. Moreover, risks and challenges associated with primary and secondary Firm Frequency Response (FFR) mechanisms, where the load is rapidly shed at high speed in response to changes in grid frequency, is considered. For instance, measurements are included that show a significant increase in peak inrush currents of approx. 30% when the system returns to normal operation at the end of a DSR event. Consideration of how high inrush currents after a DSR event can produce voltage fluctuations of the supply and we assess risks to the local power supply system.

Keywords: Demand Side Response; Firm Frequency Response; National Grid; retail refrigeration systems; inrush current (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/2/371/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/2/371/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:2:p:371-:d:130271

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:2:p:371-:d:130271