EconPapers    
Economics at your fingertips  
 

Robust Condition Assessment of Electrical Equipment with One Class Support Vector Machines Based on the Measurement of Partial Discharges

Emilio Parrado-Hernández, Guillermo Robles, Jorge Alfredo Ardila-Rey and Juan Manuel Martínez-Tarifa
Additional contact information
Emilio Parrado-Hernández: Department of Signal Processing and Communications, Universidad Carlos III de Madrid, Avda. Universidad, 30, Leganés, Madrid 28911, Spain
Guillermo Robles: Department of Electrical Engineering, Universidad Carlos III de Madrid, Avda. Universidad, 30, Leganés, Madrid 28911, Spain; Emails: grobles@ing.uc3m.es
Jorge Alfredo Ardila-Rey: Department of Electrical Engineering, Federico Santa María Technical University, 8940000 Santiago de Chile, Chile
Juan Manuel Martínez-Tarifa: Department of Electrical Engineering, Universidad Carlos III de Madrid, Avda. Universidad, 30, Leganés, Madrid 28911, Spain; Emails: grobles@ing.uc3m.es

Energies, 2018, vol. 11, issue 3, 1-18

Abstract: This paper presents a system for the detection of partial discharges (PD) in industrial applications based on One Class Support Vector Machines (OCSVM). The study stresses the detection of Partial Discharges (PD) as they represent a major source of information related to degradation in the equipment. PD measurement is a widely extended technique for condition monitoring of electrical machines and power cables to avoid catastrophic failures and the consequent blackouts. One of the most important keystones in the interpretation of partial discharges is their separation from other signals considered as not-PD especially in low SNR measurements. In this sense, the OCSVM is an interesting alternative to binary SVMs since it does not need a training set with examples of all the output classes correctly labelled. On the contrary, the OCSVM learns a model of the signals acquired when the equipment is in PD-free mode, defined as a state where no degradation mechanism is active, so one only needs to make sure that the training signals were recorded under this setting. These default mode signals are easier to characterize and acquire in industrial environments than PD and lead to more robust detectors that practically do not need domain adaptation to perform in scenarios prone to different types of PD. In fact, the experimental results show that the performance of the OCSVM is comparable to that achieved by a binary SVM trained using both noise and PD pulses. Finally, the method is successfully applied to a more realistic scenario involving the detection of PD in a damaged distribution power cable.

Keywords: One Class Support Vector Machines (OCSVM); noise characterization; partial discharge discrimination; electrical asset monitoring; early fault prevention (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/3/486/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/3/486/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:3:p:486-:d:133250

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:3:p:486-:d:133250