EconPapers    
Economics at your fingertips  
 

A Commutation Failure Suppression Control Method Based on the Controllable Operation Region of Hybrid Dual-Infeed HVDC System

Chao Xiao, Xiaofu Xiong, Jinxin Ouyang, Getu Ma, Di Zheng and Ting Tang
Additional contact information
Chao Xiao: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 40044, China
Xiaofu Xiong: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 40044, China
Jinxin Ouyang: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 40044, China
Getu Ma: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 40044, China
Di Zheng: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 40044, China
Ting Tang: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 40044, China

Energies, 2018, vol. 11, issue 3, 1-13

Abstract: With the increased use of high voltage direct current (HVDC) systems, line commutated converters (LCC-HVDC) and voltage source converters (VSC-HVDC) tend to feed into AC systems over short electrical distances. The flexible power control of VSC-HVDC systems provides an effective approach to suppress the commutation failure of LCC-HVDC systems. A suppression method, based on a controllable operation region, is proposed in this study to reduce the probability of commutation failure in a hybrid dual-infeed HVDC system. First, the quantitative transient reactive power control requirement of VSC-HVDC inverter that could fulfill the suppression control boundary condition of commutation failure was analyzed. Given the maximum current constraint of the VSC-HVDC inverter and the primary frequency modulation constraint of the sending-end grid, a controllable operation region of the hybrid dual-infeed HVDC system was proposed. Furthermore, a commutation failure suppression control method, based on the controllable operation region, was proposed to mitigate continuous commutation failure. Finally, the validity and accuracy of the proposed method was verified by the simulation of PSCAD/EMTDC. The proposed control method can realize reasonable use of the reactive power control capability of the VSC-HVDC system, which effectively improves immunity to commutation failure of the LCC-HVDC system under grid fault.

Keywords: line commutated converter for high voltage direct current (LCC-HVDC); voltage source converter for high voltage direct current (VSC-HVDC); hybrid dual-infeed HVDC system; controllable operation region; commutation failure (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/3/574/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/3/574/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:3:p:574-:d:135067

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:3:p:574-:d:135067