Research on Optimal Wind Power Penetration Ratio and the Effects of a Wind-Thermal-Bundled System under the Constraint of Rotor Angle Transient Stability
Ming Ding,
Yan Zhang,
Pingping Han,
Yuying Bao and
Haitian Zhang
Additional contact information
Ming Ding: Anhui Provincial Laboratory of New Energy Utilization and Energy Conservation, Hefei University of Technology, Hefei 230009, China
Yan Zhang: Anhui Provincial Laboratory of New Energy Utilization and Energy Conservation, Hefei University of Technology, Hefei 230009, China
Pingping Han: Anhui Provincial Laboratory of New Energy Utilization and Energy Conservation, Hefei University of Technology, Hefei 230009, China
Yuying Bao: State Grid Anhui Zhongxing Electric Power Design Institute Co., Ltd., Hefei 230022, China
Haitian Zhang: Anhui Provincial Laboratory of New Energy Utilization and Energy Conservation, Hefei University of Technology, Hefei 230009, China
Energies, 2018, vol. 11, issue 3, 1-22
Abstract:
Large-scale wind-thermal-bundled power that is transmitted by mixed ultra-high voltage direct current (UHVDC)/ultra-high voltage alternating current (UHVAC) systems has become crucial for large-scale wind farms in China. Equations describing the electromagnetic power characteristics under short circuits for UHVAC lines and UHVDC blocks are derived based on an analysis of the external characteristics of a doubly fed wind farm and UHVDC systems. The effect of wind power penetration ratio on rotor angle transient stability is analysed, and the optimal wind power penetration ratio under the constraint of rotor angle transient stability is determined. The effects of system parameters, such as the UHVDC transmission capacity and the reactance of UHVAC lines on the optimal wind power penetration ratio are discussed. The trend of rotor angle stability varies from a monotonic deterioration to concave, and the optimal wind power penetration ratio increases from 0 to 30% under an UHVDC block when the reactance of UHVAC lines increases from 0.005 to 0.02. The optimal wind power penetration ratio under a short circuit increases from 40% to 60% when the reactance of UHVAC lines decreases from 0.02 to 0.006 and decreases from 40% to 30% when the capacity of UHVDC decreases from 3200 MW to 1600 MW. The analysis is verified by simulating an actual system in China’s Northwest Power Grid.
Keywords: wind-thermal-bundled system; mixed UHVDC/UHVAC system; wind power penetration ratio; electromagnetic power equation; angle transient stability (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/11/3/666/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/3/666/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:3:p:666-:d:136498
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().