EconPapers    
Economics at your fingertips  
 

Nonlinear Robust Control for Low Voltage Direct-Current Residential Microgrids with Constant Power Loads

Martín-Antonio Rodríguez-Licea, Francisco-Javier Pérez-Pinal, Jose-Cruz Nuñez-Perez and Carlos-Alonso Herrera-Ramirez
Additional contact information
Martín-Antonio Rodríguez-Licea: CONACYT-Instituto Tecnológico de Celaya, Celaya, Guanajuato 38010, Mexico
Francisco-Javier Pérez-Pinal: Departamento de Electrónica, Instituto Tecnológico de Celaya, Celaya, Guanajuato 38010, Mexico
Jose-Cruz Nuñez-Perez: Instituto Politécnico Nacional, IPN-CITEDI, Tijuana, Baja California 22435, Mexico
Carlos-Alonso Herrera-Ramirez: CONACYT-Instituto Tecnológico de Celaya, Celaya, Guanajuato 38010, Mexico

Energies, 2018, vol. 11, issue 5, 1-20

Abstract: A Direct Current (DC) microgrid is a concept derived from a smart grid integrating DC renewable sources. The DC microgrids have three particularities: (1) integration of different power sources and local loads through a DC link; (2) on-site power source generation; and (3) alternating loads (on-off state). This kind of arrangement achieves high efficiency, reliability and versatility characteristics. The key device in the development of the DC microgrid is the power electronic converter (PEC), since it allows an efficient energy conversion between power sources and loads. However, alternating loads with strictly-controlled PECs can provide negative impedance behavior to the microgrid, acting as constant power loads (CPLs), such that the overall closed-loop system becomes unstable. Traditional CPL compensation techniques rely on a damping increment by the adaptation of the source or load voltage level, adding external circuitry or by using some advanced control technique. However, none of them provide a simple and general solution for the CPL problem when abrupt changes in parameters and/or in alternating loads/sources occur. This paper proposes a mathematical modeling and a robust control for the basic PECs dealing with CPLs in continuous conduction mode. In particular, the case of the low voltage residential DC microgrid with CPLs is taken as a benchmark. The proposed controller can be easily tuned for the desired response even by the non-expert. Basic converters with voltage mode control are taken as a basis to show the feasibility of this analysis, and experimental tests on a 100-W testbed include abrupt parameter changes such as input voltage.

Keywords: robust control; DC-DC converter; constant power load; low voltage direct-current residential microgrid (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/5/1130/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/5/1130/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:5:p:1130-:d:144353

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:5:p:1130-:d:144353