EconPapers    
Economics at your fingertips  
 

Service Continuity of PV Synchronous Buck/Buck-Boost Converter with Energy Storage †

Saima Siouane, Slaviša Jovanović and Philippe Poure
Additional contact information
Saima Siouane: Institut Jean Lamour (UMR7198), Université de Lorraine Vandoeuvre lès Nancy, Campus Artem - BP 50840, F-54511 Nancy, France
Slaviša Jovanović: Institut Jean Lamour (UMR7198), Université de Lorraine Vandoeuvre lès Nancy, Campus Artem - BP 50840, F-54511 Nancy, France
Philippe Poure: Institut Jean Lamour (UMR7198), Université de Lorraine Vandoeuvre lès Nancy, Campus Artem - BP 50840, F-54511 Nancy, France

Energies, 2018, vol. 11, issue 6, 1-20

Abstract: Numerous advantages offered by Photovoltaic (PV) generation systems coupled with the increasing power demands for clean energy put PV systems in the front of many research works. For stand-alone applications powered with PV systems, the reliability of the power conversion stage is essential to ensure the continuous supply of energy. Therefore, in the case of any failure occurring in the power conversion stage, it is mandatory to provide remedial actions to guarantee the service continuity of the produced electrical power. This paper analyses the service continuity of a two-stage buck/buck-boost converter with energy storage, driven with synchronous control. The initial two-stage converter is made fault-tolerant and robust to failures of its two switches by adding only one additional switch associated with two diodes. In this study, only open-circuit switch faults are considered. The proposed fault-tolerant circuit and the initial one have the same electrical behavior when synchronous control is used. The applied synchronous control in both healthy conditions and post-fault operation ensures the same functionalities without degrading the system’s performances. The proposed two-stage synchronously-controlled circuit is validated through simulation in the cases of open circuit faults on the two switches of the initial converter. The obtained results show the feasibility of the proposed functional redundancy and the continuity of operation at full power after switch fault diagnosis.

Keywords: service continuity; open circuit switch failure; fault-tolerant operation; synchronous control; DC-DC converter; PV modules (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/6/1369/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/6/1369/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:6:p:1369-:d:149361

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:6:p:1369-:d:149361