EconPapers    
Economics at your fingertips  
 

Study on the Propagation Characteristics of Partial Discharge in Switchgear Based on Near-Field to Far-Field Transformation

Yang Qi, Yang Fan, Bing Gao, Yang Mengzhuo, Ammad Jadoon, Yu Peng and Tian Jie
Additional contact information
Yang Qi: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China
Yang Fan: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China
Bing Gao: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China
Yang Mengzhuo: Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT 06269-4157, USA
Ammad Jadoon: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China
Yu Peng: Shenzhen Power Supply Bureau Co., Ltd., Shenzhen 518000, China
Tian Jie: Shenzhen Power Supply Bureau Co., Ltd., Shenzhen 518000, China

Energies, 2018, vol. 11, issue 7, 1-12

Abstract: Ultra-high frequency (UHF) electromagnetic (EM) signals generated by the partial discharge (PD) process of high-voltage equipment are now widely used in PD detection. The computation of EM propagation generated by a local discharge source using a uniformly hardwiring source can hardly reveal the discharge characteristics. In this paper, a method of near-field to far-field transformation is proposed to realize the study of the propagation characteristics of the PD signal. A short gap discharge model is established to get the near-field electromagnetics and the proposed method is validated by comparing the directly calculated results with the results of the near-field source. In the end, a model of switchgear is employed to study the propagation characteristics of the EM signal based on the proposed method. Via numerical calculation, the influence of the equipment in the switchgear on the propagation of the discharge EM is studied. It is found that the direction of the discharge source has a significant effect on the distribution of the electric field, which indicates that the discharge source cannot be simplified to a uniformly hardwiring source. In addition, it is also obtained that the amplitude of the electric field shows the same trend with the growth of the discharge channel, which gives a method for evaluating the development of the PD. Particularly, the near-field to far-field transformation can provide an effective method for studying the propagation of discharge EM waves in large-scale equipment.

Keywords: partial discharge; near-field; far-field; Huygens’ surface; propagation characteristics (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/7/1619/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/7/1619/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:7:p:1619-:d:153588

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:7:p:1619-:d:153588