Feature Extraction and Comprehension of Partial Discharge Characteristics in Transformer Oil from Rated AC Frequency to Very Low Frequency

Zhongliu Zhou, Yuanxiang Zhou, Xin Huang, Yunxiao Zhang, Mingyuan Wang and Shaowei Guo
Additional contact information
Zhongliu Zhou: State Key Lab of Electrical Power System, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
Yuanxiang Zhou: State Key Lab of Electrical Power System, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
Xin Huang: State Key Lab of Electrical Power System, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
Yunxiao Zhang: State Key Lab of Electrical Power System, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
Mingyuan Wang: State Grid Jibei Electric Economic Research Institute, Beijing 100045, China
Shaowei Guo: North China Electric Power Research Institute Co., Ltd., Beijing 100045, China

Energies, 2018, vol. 11, issue 7, 1-17

Abstract: The reactive current can be reduced effectively by decreasing the frequency of the voltage in partial discharge (PD) test, especially for equipment with large capacitance. Thus, the cost and volume of the test power supply can be economized. To figure out the difference of PD characteristics in transformer oil between rated alternating-current (AC) frequency (50 Hz) and low frequency, tests are conducted from rated AC frequency to very low frequency (0.1 Hz) based on impulse current method. The results show that with the decrease of frequency, the inception voltage increases. The maximum and mean magnitude of discharge and pulse repetition rate first increase slightly, then decrease obviously. The main features of the variation of phase resolved PD (PRPD) patterns, discharge statistical patterns (phase distribution of maximum and mean discharge magnitude, pulse repetition rate q max – φ , q mean – φ , n – φ ; and number distribution of discharge magnitude n – q ), and their characteristic parameters (skewness S k + , S k − ; kurtosis K u + , K u − ; asymmetry A sy ; and correlation coefficient C c ) are depicted in detail, which should be paid attention to when using low frequency voltage. The inner mechanism for these variations is discussed from the aspects of the influence on electric field distribution and discharge process of frequency. Additionally, the variation trend of PD characteristics with the decrease of frequency can provide more information about insulation defect, which can be the supplement for discharge mode recognition.

Keywords: partial discharge; low frequency voltage; PRPD; characteristic parameter; insulation defect diagnosis (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/7/1702/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/7/1702/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:7:p:1702-:d:155499

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:7:p:1702-:d:155499