EconPapers    
Economics at your fingertips  
 

Imaging the Corrosion in Grounding Grid Branch with Inner-Source Electrical Impedance Tomography

Xing Li, Fan Yang, Julan Ming, Ammad Jadoon and Sheng Han
Additional contact information
Xing Li: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China
Fan Yang: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China
Julan Ming: Hangzhou Yineng Electric Technology Co., Ltd., Hangzhou 310014, China
Ammad Jadoon: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China
Sheng Han: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China

Energies, 2018, vol. 11, issue 7, 1-13

Abstract: The corrosion diagnosis of grounding grid can locate the corroded branches and provide guidance for the maintenance and repair of the grounding grid. This paper proposed the electrical impedance tomography (EIT) method on the corrosion diagnosis of grounding grid and described how it works. Firstly, the inverse problem model of the electrical impedance tomography on grounding grid is developed. Secondly, in order to weaken the ill-posedness of the inverse problem, a Newton iterative algorithm with Tikhonov regularization is proposed to solve the problem. Then, due to the high resistivity contrast between the soli and steel and the large size of imaging region, this paper presents the method of soil-separation and block-diagnosis to accomplish these problems. Finally, field experiments were carried out to verify the effectiveness of the proposed method and the results show that the location and degree of the corrosion in the grounding grid can be easily judged from the imaging results.

Keywords: corrosion diagnosis; grounding grid; electrical impedance tomography; Tikhonov regularization; soil-separation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/7/1739/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/7/1739/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:7:p:1739-:d:155896

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:7:p:1739-:d:155896