Study on Impulse Breakdown Characteristics of Internal-Gap Lightning Protection Device Applied to 35 kV Distribution Line
Zhen Fang,
Bowen Wang,
Jiazheng Lu and
Zhenglong Jiang
Additional contact information
Zhen Fang: State Key Laboratory of Disaster Prevention & Reduction for Power Grid Transmission and Distribution Equipment, Changsha 410129, China
Bowen Wang: State Key Laboratory of Disaster Prevention & Reduction for Power Grid Transmission and Distribution Equipment, Changsha 410129, China
Jiazheng Lu: State Key Laboratory of Disaster Prevention & Reduction for Power Grid Transmission and Distribution Equipment, Changsha 410129, China
Zhenglong Jiang: State Key Laboratory of Disaster Prevention & Reduction for Power Grid Transmission and Distribution Equipment, Changsha 410129, China
Energies, 2018, vol. 11, issue 7, 1-13
Abstract:
External environmental factors have no effect on the breakdown performance of the internal gap, leading to the anti-icing and anti-storm features of the internal-gap lightning protection device (ILPD). In this paper, a test platform is created to study the impulse discharge and arc erosion characteristics of the ILPD applied to a 35 kV distribution line. The 50% lightning impulse voltage and discharge stability of the ILPD are experimentally analysed. The results show that the ILPD has good discharge voltage repeatability under multiple impulses. Under a positive lightning impulse, the 50% breakdown voltage of the ILPD is 3.8–11.4% higher than that of the outer-gap lightning protection device (OLPD). A finite element simulation model is created for electric field analysis. The maximum electric field strength of the ILPD is 4.68% lower than that of the OLPD, leading to a higher lightning breakdown voltage. High-speed camera shooting shows that the discharge arc may lead to the erosion of the discharge tube, reducing its insulation performance. A large current impulse test platform is set up for arc energy analysis, which indicates that more than 90% of the energy is absorbed by the varistor during lightning stroke. The quality and leakage current of the discharge tube did not change significantly after testing. Given the current design of varistors, the per unit length energy of arc is less than 4.5 J/mm due to the numerical calculation, which is far less than the experimental arc energy (25.0 J/mm). Therefore, arc erosion will not cause the insulation performance of discharge tube to decrease when using the current varistor design.
Keywords: internal-gap; lightning protection; lightning impulse voltage; arc; high-speed camera; varistor (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)
Downloads: (external link)
https://www.mdpi.com/1996-1073/11/7/1758/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/7/1758/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:7:p:1758-:d:156178
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().