EconPapers    
Economics at your fingertips  
 

Thermal Comfort, Energy and Cost Impacts of PMV Control Considering Individual Metabolic Rate Variations in Residential Building

Sung Hyup Hong, Jong Man Lee, Jin Woo Moon and Kwang Ho Lee
Additional contact information
Sung Hyup Hong: Graduate School, Hanbat National University, San 16-1, Dukmyung-Dong, Yuseong-Gu, Daejeon 34158, Korea
Jong Man Lee: Graduate School, Hanbat National University, San 16-1, Dukmyung-Dong, Yuseong-Gu, Daejeon 34158, Korea
Jin Woo Moon: School of Architecture and Building Science, Chung-ang University, 84, Heukseok-ro, Dongjak-gu, Seoul 06974, Korea
Kwang Ho Lee: Department of Architectural Engineering, Hanbat National University, San 16-1, Dukmyung-Dong, Yuseong-Gu, Daejeon 34158, Korea

Energies, 2018, vol. 11, issue 7, 1-21

Abstract: To date, most of the indoor environment control is based on the dry-bulb air temperature, which is one of the simplified control methods having the limitation to truly represent the thermal comfort of individual occupants. A variety of factors affect the thermal comfort such as dry-bulb air temperature, humidity, air movement, radiation, clothing insulation, and metabolic activity level. In this circumstance, this study investigated the effects of considering hourly metabolic rate variations for predicted mean vote (PMV) control on the actual thermal load, energy usage, and life cycle cost (LCC). The case adopting PMV control taking the hourly metabolic rate into account was comparatively analyzed against the conventional dry-bulb air temperature control, using a detailed simulation technique after the validation process. As a result, when the activity state of the occupant is house cleaning in the summer, the indoor temperature decreases rapidly due to the high amount of activity. It requires a temperature that is 11.7 °C and 9.7 °C lower than the conventional dry-bulb air temperature control method, respectively, and generally forms a higher indoor air temperature than the conventional control method after 7 p.m. This means the difference in temperature to satisfy the comfort of the occupant according to the amount of activity, and during winter as opposed to summer, was found to form a lower indoor air temperature than the conventional temperature control. In case of annual boiler gas consumption, PMV control showed 7.3% less energy consumption than the dry-bulb air temperature control and showed 28.8% less energy consumption than the dry-bulb air temperature control for annual cooling electricity consumption. Considering the cooling and heating energy reduction rate and the initial installation cost of measuring equipment for real-time metabolic rate and PMV measurement, a payback period of approximately 4.15 years was required.

Keywords: metabolic rates; predicted mean vote (PMV); EnergyPlus; energy consumption; life cycle cost (LCC); thermal comfort (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View complete reference list from CitEc
Citations: View citations in EconPapers (8)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/7/1767/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/7/1767/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:7:p:1767-:d:156385

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:7:p:1767-:d:156385