EconPapers    
Economics at your fingertips  
 

Full- and Reduced-Order State-Space Modeling of Wind Turbine Systems with Permanent Magnet Synchronous Generator

Christoph M. Hackl, Pol Jané-Soneira, Martin Pfeifer, Korbinian Schechner and Sören Hohmann
Additional contact information
Christoph M. Hackl: Department of Electrical Engineering and Information Technology, Munich University of Applied Sciences, Lothstraße 64, 80335 München, Germany
Pol Jané-Soneira: Institute of Control Systems (IRS), Karlsruhe Institute of Technology (KIT), Kaiserstraße 12, 76131 Karlsruhe, Germany
Martin Pfeifer: Institute of Control Systems (IRS), Karlsruhe Institute of Technology (KIT), Kaiserstraße 12, 76131 Karlsruhe, Germany
Korbinian Schechner: Research Group “Control of Renewable Energy Systems”, Munich School of Engineering, Technical University of Munich, Lichtenbergstraße 4a, 85748 Garching, Germany
Sören Hohmann: Institute of Control Systems (IRS), Karlsruhe Institute of Technology (KIT), Kaiserstraße 12, 76131 Karlsruhe, Germany

Energies, 2018, vol. 11, issue 7, 1-33

Abstract: Full-order state-space models represent the starting point for the development of advanced control methods for wind turbine systems (WTSs). Regarding existing control-oriented WTS models, two research gaps must be noted: (i) There exists no full-order WTS model in form of one overall ordinary differential equation that considers all dynamical effects which significantly influence the electrical power output; (ii) all existing reduced-order WTS models are subject to rather arbitrary simplifications and are not validated against a full-order model. Therefore, in this paper, two full-order nonlinear state-space models (of 11th and 9th-order in the ( a , b , c )- and ( d , q )-reference frame, resp.) for variable-speed variable-pitch permanent magnet synchronous generator WTSs are derived. The full-order models cover all relevant dynamical effects with significant impact on the system’s power output, including the switching behavior of the power electronic devices. Based on the full-order models, by a step-by-step model reduction procedure, two reduced-order WTS models are deduced: A non-switching (averaging) 7th-order WTS model and a non-switching 3rd-order WTS model. Comparative simulation results reveal that all models capture the dominant system dynamics properly. The full-order models allow for a detailed analysis covering the high frequency oscillations in the instantaneous power output due to the switching in the power converters. The reduced-order models provide a time-averaged instantaneous power output (which still correctly reflects the energy produced by the WTS) and come with a drastically reduced complexity making those models appropriate for large-scale power grid controller design.

Keywords: wind turbine system; wind energy conversion system; dynamic modeling; control design model; control system; operation management; switching behavior; nonlinear dynamics; model reduction; comparative simulation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/11/7/1809/pdf (application/pdf)
https://www.mdpi.com/1996-1073/11/7/1809/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:11:y:2018:i:7:p:1809-:d:157274

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:11:y:2018:i:7:p:1809-:d:157274