EconPapers    
Economics at your fingertips  
 

Influence of DC Electric Fields on Pollution of HVDC Composite Insulator Short Samples with Different Environmental Parameters

Xinhan Qiao, Zhijin Zhang, Xingliang Jiang and Tian Liang
Additional contact information
Xinhan Qiao: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China
Zhijin Zhang: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China
Xingliang Jiang: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China
Tian Liang: State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China

Energies, 2019, vol. 12, issue 12, 1-12

Abstract: Pollution-induced flashover is a serious threat to the safe operation of power systems. With the development of High Voltage Direct Current (HVDC), it is necessary to study insulator contamination in DC electric fields. In this paper, the energized wind tunnel contamination test was conducted in order to systematically study the pollution ratio, k (ratio of non-soluble deposit density (NSDD) of a DC-energized condition to a non-energized condition), under different environmental parameters. Later, a two-dimensional contamination model of short samples of an HVDC composite insulator was established. The particle motion characteristics under different environmental parameters were then analyzed by the finite element method (FEM). The research results showed that—the DC electric field had an influence on particle motion but in different environments, the degree of influence was different. In addition, k was found to largely vary, with a variation in the environmental parameters. When the electrical stress ( E s ) increased from 0 to 70 kV/m, k increased gradually. However, when the wind speed ( w s ) increased, k experienced a decreasing trend. Finally, as the particle diameter ( d p ) decreased, k increased at first, followed by a decrease, and then again showed an increase. The results of the pollution ratio, k , for different environmental parameters are of great importance for guiding anti-pollution work in power systems.

Keywords: contamination; pollution ratio k; HVDC composite insulators; particles motion process; electric field (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)

Downloads: (external link)
https://www.mdpi.com/1996-1073/12/12/2304/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/12/2304/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:12:p:2304-:d:240376

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:12:y:2019:i:12:p:2304-:d:240376