Influence of Acetone and Sodium Chloride Additives on Cooling Efficiency of Water Droplets Impinging onto Hot Metal Surfaces
Joachim Søreng Bjørge,
Svein Arne Bjørkheim,
Maria-Monika Metallinou,
Torgrim Log and
Øyvind Frette
Additional contact information
Joachim Søreng Bjørge: Q Rådgivning AS/PDS Protek, Øvregata 126, 5527 Haugesund, Norway
Svein Arne Bjørkheim: Omega Areal AS, Kvassanesvegen 4, 5582 Ølensvåg, Norway
Maria-Monika Metallinou: Western Norway University of Applied Sciences, Fire Disaster Research Group, 5528 Haugesund, Norway
Torgrim Log: Western Norway University of Applied Sciences, Fire Disaster Research Group, 5528 Haugesund, Norway
Øyvind Frette: Department of Physics and Technology, University of Bergen, 5020 Bergen, Norway
Energies, 2019, vol. 12, issue 12, 1-16
Abstract:
In the present work, the cooling efficiency of water droplets falling onto hot aluminum and stainless steel discs from heights of 12.5 cm, 25 cm, 50 cm and 100 cm, corresponding to speeds of 1.5 m/s, 2.2 m/s, 3.1 m/s and 4.4 m/s, respectively, were studied. The discs were aligned at 0° (horizontal), 30° and 60° inclination. The water application rate was 0.022 g/s and the droplet diameters studied were 2.5 mm, 3.2 mm and 3.7 mm. Acetone solutions (300 ppm and 700 ppm) as well as a NaCl (35 g/kg) solution, emulating seawater, were tested to evaluate the influence of an active surfactant on the recorded cooling efficiency. The droplets with higher impact speed resulted in lower cooling efficiency, especially at disc temperatures above the Leidenfrost temperature, likely due to more vigorous droplets bouncing. Larger inclination did, as expected, result in lower cooling efficiency. At temperatures associated with nucleate boiling, the water droplets with NaCl conspicuously displayed higher cooling efficiency at about 110 °C. However, at temperatures between 120 °C and the Leidenfrost temperature, acetone and NaCl additives did not significantly alter the cooling efficiency of the water droplets. Above the Leidenfrost temperature, a minor increase in cooling efficiency was observed for the acetone solutions. Overall, the additives only marginally changed the water droplet cooling efficiency. The standard industrial water application rate (i.e., 10 L/min?m 2 ) is shown to be insufficient compared to the heat fluxes expected in pool and jet fires (i.e., 250 kW/m 2 and 350 kW/m 2 , respectively).
Keywords: hot metals; water droplet cooling efficiency; acetone; NaCl (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/12/12/2358/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/12/2358/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:12:p:2358-:d:241291
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().