Analysis and Mitigation of Subsynchronous Resonance in a Korean Power Network with the First TCSC Installation
Minh-Quan Tran,
Minh-Chau Dinh,
Seok-Ju Lee,
Jea-In Lee,
Minwon Park,
Chur Hee Lee and
JongSu Yoon
Additional contact information
Minh-Quan Tran: Department of Electrical Engineering, Changwon National University, Changwon 51140, Korea
Minh-Chau Dinh: Department of Electrical Engineering, Changwon National University, Changwon 51140, Korea
Seok-Ju Lee: Department of Electrical Engineering, Changwon National University, Changwon 51140, Korea
Jea-In Lee: Department of Electrical Engineering, Changwon National University, Changwon 51140, Korea
Minwon Park: Department of Electrical Engineering, Changwon National University, Changwon 51140, Korea
Chur Hee Lee: Korea Electric Power Research Institute, Seoul 34056, Korea
JongSu Yoon: Korea Electric Power Research Institute, Seoul 34056, Korea
Energies, 2019, vol. 12, issue 15, 1-16
Abstract:
This paper presents a detailed analysis results of the effect of a thyristor-controlled series capacitor (TCSC) on subsynchronous resonance (SSR), which was first applied to a Korean power system. First, the TCSC parameters were calculated, the structure of TCSC with synchronous voltage reversal (SVR) controller was presented, and the torsional characteristics of Hanul nuclear power generator rotor were studied to investigate the natural frequency and mode shape. The test signal method was used to determine the electrical damping in the frequency range of SSR operation through an electromagnetic transient analysis program in various system configurations. The SSR phenomenon was analyzed by comparing the electrical and mechanical damping of a conventional fixed series capacitor (FSC), and the case of a TCSC installed, and the effectiveness of the TCSC without any risk of SSR was demonstrated. As a result, when installing FSC, SSR occurred under sensitive operating conditions, but SSR was prevented in the case of TCSC compensation with SVR. The results obtained in this study can be effectively applied to the installation of TCSC in real power systems.
Keywords: korean power system; subsynchronous resonance (SSR); synchronous voltage reversal (SVR); thyristor controlled series capacitor (TCSC); test signal method (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1996-1073/12/15/2847/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/15/2847/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:15:p:2847-:d:251146
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().