EconPapers    
Economics at your fingertips  
 

Enhancement of DUBAL Network Operational Performance Using Resistive High Temperature Superconducting Fault Current Limiter

Hamood Naji, Noureddine Harid and Huw Griffiths
Additional contact information
Hamood Naji: EGA Aluminum, Dubai 3627, UAE
Noureddine Harid: Khalifa University, APEC Centre, Department of Electrical and Computer Engineering, Abu Dhabi 127788, UAE
Huw Griffiths: Khalifa University, APEC Centre, Department of Electrical and Computer Engineering, Abu Dhabi 127788, UAE

Energies, 2019, vol. 12, issue 15, 1-13

Abstract: Power systems under expansion suffer from escalating fault levels that impact equipment integrity, operational flexibility, and the overall security of the system. The fault current limiter (FCL) is one of approaches used by utilities to limit fault current levels and in Dubai Aluminum (DUBAL) series current limiting reactors are currently used. However, more effective (FCL) topologies are sought and, in this paper, a case study is proposed using resistive high temperature superconducting fault current limiters (HT-SFCLs). The application of HT-SCFLs is aimed here at reducing short-circuit currents, while at the same time enhancing the stability and security of the network. The study involves analysis of three-phase and single-line-to-ground faults, evaluation of the voltage levels and total harmonic distortion (THD) levels at busbars considering different fault scenarios, and demonstrates how the use of HT-SFCLs at various locations improves the plant performance. The ideal HT-SFCL model is adopted for this analysis since the aim is to look at the steady-state performance rather than the transient performance. Comparison with series reactor FCLs which are currently installed in the plant show better performance with the proposed HT-SFCL. Voltage profile values and total harmonic content were also compared with measurement data available at the plant.

Keywords: fault current limiter; high temperature superconductors; reactor; industrial power plant; symmetrical and asymmetrical faults (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/12/15/3007/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/15/3007/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:15:p:3007-:d:254647

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:12:y:2019:i:15:p:3007-:d:254647