EconPapers    
Economics at your fingertips  
 

Cooling Performance Enhancement of Air-Cooled Condensers by Guiding Air Flow

Xianwei Huang, Lin Chen, Lijun Yang, Xiaoze Du and Yongping Yang
Additional contact information
Xianwei Huang: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, Ministry of Education, Beijing 102206, China
Lin Chen: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, Ministry of Education, Beijing 102206, China
Lijun Yang: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, Ministry of Education, Beijing 102206, China
Xiaoze Du: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, Ministry of Education, Beijing 102206, China
Yongping Yang: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, Ministry of Education, Beijing 102206, China

Energies, 2019, vol. 12, issue 18, 1-28

Abstract: Adverse wind effects on the thermo-flow performances of air-cooled condensers (ACCs) can be effectively restrained by wind-proof devices, such as air deflectors. Based on a 2 × 300 MW coal-fired power generation unit, two types (plane and arc) of air deflectors were installed beneath the peripheral fans to improve the ACC’s cooling performance. With and without air deflectors, the air velocity, temperature, and pressure fields near the ACCs were simulated and analyzed in various windy conditions. The total air mass flow rate and unit back pressure were calculated and compared. The results show that, with the guidance of deflectors, reverse flows are obviously suppressed in the upwind condenser cells under windy conditions, which is conducive to an increased mass flow rate and heat dissipation and, subsequently, introduces a favorable thermo-flow performance of the cooling system. When the wind speed increases, the leading flow effect of the air deflectors improves, and improvements in the ACC’s performance in the wind directions of 45° and −45° are more satisfactory. However, hot plume recirculation may impede performance when the wind direction is 0°. For all cases, air deflectors in an arc shape are recommended to restrain the disadvantageous wind effects.

Keywords: Ambient wind; air-cooled condenser; air deflector; reverse flow; hot plume recirculation; thermo-flow performances (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/12/18/3503/pdf (application/pdf)
https://www.mdpi.com/1996-1073/12/18/3503/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:12:y:2019:i:18:p:3503-:d:266353

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:12:y:2019:i:18:p:3503-:d:266353